jrsteensen / OpenHornet

OpenHornet 1:1 F/A-18C Simulator Repository
https://www.openhornet.com
Other
316 stars 110 forks source link

[Bug]: 3D models for switch TL1240GQ on the DDI pcb are in the wrong orientation in KiCad #1084

Open MartelSimon opened 2 months ago

MartelSimon commented 2 months ago

Discord Username

1_neox_1

Bug Summary

The 3D models for the switch TL1240GQ inside KiCad for the DDI pcb are in the wrong direction and are misleading.

Expected Results

The 3D models for the switch TL1240GQ inside KiCad for the DDI pcb should follow the manufacturer datasheet. (https://www.mouser.ca/datasheet/2/140/TL1240GQ-3458821.pdf https://eswitch.wpengine.com/wp-content/uploads/2022/06/TL1240.pdf)

Actual Results

The long lead (anode according to the manufacturer datasheet) on the 3D model is not on the positive source and is on the cathode position / GND.

Screenshots/Images/Files

image image image image

Applicable Part Numbers

OH1A3-1

Release Version

v0.2.0

Category

Electrical (PCBs/Wiring/etc)

Applicable End Item(s)

Upper Instrument Panel (UIP)

Built to print?

Miscellaneous Info

No response

kbastronomics commented 2 months ago

Verified the 3D model is rotated 180 degree's from where it should be. i already have the PCB file updated and will submit a pull request for it.

jrsteensen commented 1 month ago

@kbastronomics If you could go ahead and make the changes to MCAD by integrating the new PCB in the model. If any drawings are Rev - that are impacted, please rev them to Rev A as well, then submit the updated ECAD & release package drawings. No Master BOM updates should be required.