junglegobs / ASoSEPOC

Interaction betwen resource adequacy and security of supply task in the EPOC project.
1 stars 0 forks source link

Load shedding for full year model but not for single day model #13

Open junglegobs opened 2 years ago

junglegobs commented 2 years ago

This is the results for the day selection (not that the load was multiplied by 1.5):

days_for_analysis.csv

Clearly there is load shedding for day 285, 1,247 MWh to be precise. However, in my analysis of day 285 I don't observe this load shedding! See here for:

no_OR.csv

This could of course be due to the cyclic storage constraints, but still... suspicious.