kbenne / cbecc

Automatically exported from code.google.com/p/cbecc
0 stars 0 forks source link

U-Value error in Baseline Construction - 'OtherFloorU071' #351

Closed GoogleCodeExporter closed 9 years ago

GoogleCodeExporter commented 9 years ago
An error was encountered while trying to simulate the 
00200-OfficeSmall-CECRefProp model with the baseline constructions assigned as 
a minimally compliant proposed construction. 

The 'OtherFloorU071' construction evaluates to a calculated U-value of 
U-0.0710227 causing an CHECKCODE error. The code required minimum is U-0.071.

Please find attached files outlining the issues related to this. 

Original issue reported on code.google.com by sand...@360-analytics.com on 18 Nov 2013 at 8:03

Attachments:

GoogleCodeExporter commented 9 years ago
Hi Sandeep,
I just fixed this issue.  Let me know if you have any questions.
Please "DoneVerified" this issue if you approve the fix.
Thanks,
Noah

Original comment by ncz...@archenergy.com on 20 Nov 2013 at 8:08

GoogleCodeExporter commented 9 years ago
I believe the issue causing the error has been fixed, but the name of the 
compliance insulation material is suffixed with the R-Value, and thus would 
have to be changed from 'Compliance Insulation R9.83' to 'Compliance Insulation 
R9.84' after the correction to the R-Value.

Original comment by sand...@360-analytics.com on 20 Nov 2013 at 9:25

GoogleCodeExporter commented 9 years ago
The r-value was changed from 9.83 to 9.831, so I don't think a name change is 
necessary. 

Original comment by rhedr...@archenergy.com on 20 Nov 2013 at 9:47

GoogleCodeExporter commented 9 years ago
The'Compliance Insulation R9.83' in the MaterialData.csv reports a R-value of 
9.835 for , so does the .xml file/s generated post simulation.

The UserInterface round up the R-value of the material to R-9.84.

Original comment by sand...@360-analytics.com on 20 Nov 2013 at 10:19

GoogleCodeExporter commented 9 years ago
Hi Sandeep,
I just updated a revised MaterialData.csv and .xlsx that fixes the rounding 
error that you were seeing.  Now the displayed R-Value for "Compliance 
Insulation R9.83" will be 9.83 (actually 9.8349, but 9.83 on the CBECC screen).

Please "DoneVerified" this issue if you deem it complete.
Noah

Original comment by ncz...@archenergy.com on 20 Nov 2013 at 11:25

GoogleCodeExporter commented 9 years ago

Original comment by sand...@360-analytics.com on 21 Nov 2013 at 5:11