Recirc. Water Heater - TDV missing #352

Open GoogleCodeExporter opened 9 years ago

GoogleCodeExporter commented 9 years ago
Scott,

When I simulate a Mid-rise Residential Building with recirculating water 
heaters the Energy Use Summary Screen shows no values for both the Proposed and 
Standard Design kTDV/ft2-yr.

Site (therms) for the Recirc. Water Heater Proposed Design and Standard Design 
do seem to be displayed accurately.

** Note: Nonrecirculating Water Heaters show values accurately for both Site 
and TDV in the Energy Use Summary screen.

There is a Recirc Water Heater prototype here:
\CBECC-Com13\Projects\Recirc Water Heater Examples\MidRiseRes - 2 recirc - 1 
nonrecirc.cibd

I have also attached a Word doc that shows this issue and it's results step by 
step.

Noah

Original issue reported on code.google.com by ncz...@archenergy.com on 18 Nov 2013 at 10:33

Attachments:

GoogleCodeExporter commented 9 years ago
Fixed in version 3 (642) - 8/19/14 AM
Changes to compliance manager DLL to include energy use simulated via the 
T24DHW engine in the hourly energy use used to calculate TDV during compliance 
analysis.

Original comment by scriswel...@gmail.com on 19 Aug 2014 at 4:28