There are 3 issues that I see in your model:
1. For the Office Service Water system you have a FluidSys:Type = “Return”.
That FluidSys:Type should be = “MakeupFluid” with the Source =
“MunicipalWater”.
2. You have floor multipliers set on the Envelope tab but you do not have any
system multipliers on the Mechanical tab. This may cause some sizing or flow
rate errors where a system is serving a space with a floor multiplier.
3. The latest version of CBECC-Com (v3a) will have the building floor area
calculation error that you are seeing fixed. This bug should not change your
compliance margin once you get the model to simulate.