System type 4 COP incorrectly calculated for baseline #865

Closed GoogleCodeExporter closed 9 years ago

GoogleCodeExporter commented 9 years ago
***********Please select Version number and Issue Type below by adding
appropriate labels*************************

What steps reproduce the problem?
1. Run Standard Test Case 020032-OffSml-S901GElectric
2. Verify Coil:Heating:DX:SingleSpeed COP
3. COP appears to be hard coded to 5

What version of CBECC-901 are you using? On what operating system?
CBECC-Com 2013-3a(678)

Please provide any additional information below.

Original issue reported on code.google.com by supriya....@pnnl.gov on 2 Dec 2014 at 2:38

GoogleCodeExporter commented 9 years ago
Roger,
If you plan to address this and other issues with DX or HeatPump coils, I 
recommend creating an alternate '-S901G.rule' files. It appears the rules for 
901 deviate more in these areas from T24 rules, and in this case, I have found 
separate rule files is an easier way to track this.

Original comment by da...@360-analytics.com on 2 Dec 2014 at 5:57

GoogleCodeExporter commented 9 years ago
I am not seeing this.  When I ran this model, the COP is 3.4 (Actually EIR is 
0.293402).  What makes you say the COP is hard coded to 5?

Original comment by rhedr...@archenergy.com on 3 Dec 2014 at 12:33

GoogleCodeExporter commented 9 years ago
Roger- Looks like I'm not doing something correctly. David didn't see the fan 
curve issue I pointed out as well. Could you please send me a short step by 
step description for updating SVN, compiling the code- I want to make sure I'm 
not missing anything

Original comment by supriyag...@gmail.com on 3 Dec 2014 at 12:54

GoogleCodeExporter commented 9 years ago
I re-ran this test and verified that the issue isn't present anymore. I think 
it was related to not compiling the code correctly. 

Original comment by supriya....@pnnl.gov on 3 Dec 2014 at 5:14

GoogleCodeExporter commented 9 years ago

Original comment by rhedr...@archenergy.com on 3 Dec 2014 at 5:15