The number of temperature sensors that read the temperature was reduc… #394

Closed mara-sys closed 1 year ago

mara-sys commented 1 year ago

…ed from five to three.

PR描述:

Fixed the problem that the value read back by the sip board temperature sensor was incorrect.

详细描述:

The power supply pins of the first two temperature sensors in the sip chip are floating, so instead of reading the average value of five temperature sensors in the original drive, read the average value of three temperature sensors.

关联issue:

393

fix #X