kike-canaries / canairio_sensorlib

Particle sensor manager for multiple sensors: Honeywell, Plantower, Panasonic, Sensirion, etc. This is sensors layer of CanAirIO project too.
https://canair.io/docs/sensorlib.html
GNU General Public License v3.0
37 stars 12 forks source link

[Wire.cpp:204] begin(): Bus already started in Master Mode. #177

Open hpsaturn opened 11 months ago

hpsaturn commented 11 months ago

Overview

On verbose mode we have many messages around this:

Log output

09:53:50.518 > [552976][I][main.cpp:169] onSensorDataOk(): [MAIN] onSensorDataOk
09:53:50.518 > -->[WIFI] AP RSSI signal         : -71 dBm
09:53:50.518 > -->[HEAP] LOOP bytes used        : 0000b/060Kb
09:53:51.669 > -->[BATT] Battery voltage        : 4.946v vref: 1107 Charge:100
09:53:52.689 > -->[SLIB] GCJA5 read             : done! 
09:53:55.496 > -->[SLIB] BME680 read            : done! 
09:53:55.496 > [557949][W][Wire.cpp:204] begin(): Bus already started in Master Mode.
09:53:55.496 > [557950][W][Wire.cpp:204] begin(): Bus already started in Master Mode.
09:53:55.496 > -->[SLIB] sensors values         : PM1:0.0 PM2.5:0.0 PM10:1.0 T:25.9 H:32.6 P:1006.7 Gas:1604.1 Alt:54.3 
09:53:55.518 > -->[SLIB] sensors count          : 2 (GCJA5,BME680,)
09:53:55.518 > -->[SLIB] sensors units count    : 8 (PM1,PM2.5,PM10,T,H,P,Gas,Alt,)
09:53:55.518 > [557976][I][main.cpp:169] onSensorDataOk(): [MAIN] onSensorDataOk