Closed bilou95 closed 3 years ago
Hi Bilou95,
I have the same issue. Did you succeed to solve the issue since then?
Thx. vfd7
At the line 115 :
"TMP_ROOM": "T5"
I replace T5 by T1. You can verify the value by consulting .lua command :
CBOX_IP/cgi-bin/sendmsg.lua?cmd=GET+ALLS and then searching the value indicated on the stove's screen.
Skarab22,
Thank you very much for your reply. I just did the fix and it works perfectly.
Thx. vfd7.
Perfect. Thanks you so much Skarab22, It's effecitvely solve the issue. I have the right value now.
Thanks you for your work. I have a Cbox with version 2.4.1 connected to a palazzetti Ines. I was able to get most of the predefine variable and also able to start/stop the heater with success. I got also by example the status and number of consumed pellet.
but the room temperature is not showed. Do you have any advice ?