Open K0SSL opened 3 years ago
I have the same problem. I did try to edit some of the code in the configuration file:
I'll let you know if I find something, but I'm not counting on it. so if anyone else can help us out?
Exactly same issue. Weirdest thing is that it started doing it after "Restore defaults" was applied. I tried reinitiating eeprom etc, but nothing helped. But previously this firmware was working fine for me :-/
So in my case it was loose connection to one of the bed leveling probe cables.
(DE) Hallo knutwurst, ich habe alle Schritte genau befolgt, jedoch spinnt mein Kossel Linear Plus (keine Ultrabase, Probe Typ 1 mit -19.00 Offset ) beim Auto-Bed-Leveling (Configuration -> Delta Calibration -> Auto Calibration). Sobald ich den Sensor anbringe und dem Drucker das Anbringen bestätige fährt er erst ganz hoch, berührt die Endstops jeweils einmal, fährt dann ungefähr in die Mitte, anschließend erst in 2-3 kleinen Schritten wieder hoch. Oben angekommen fährt er gegen die Endstops und bleibt dort auch, ohne die schalter wieder "loszulassen" wie er es bei einem normalen Homing z.b. machen würde. Während des Vorgangs erscheint auf dem Display "Iteration: 01". Nachdem er nicht weiterkommt sagt er wieder "stow probe" und wenn man das Bestätigt erhält man die Nachricht "probing failed" und er bewegt sich nicht weiter. Ich habe bereits mehrfach die Software neu aufgespielt, EEPROM initialisiert und auch den "Papiertest" gemacht und den richtigen Probe Z Offset korrekt eingetragen. Am Code habe ich nichts verändert (habe null Programmier-Erfahrung). Über Hilfe oder eine Rückmeldung würde ich mich sehr Freuen