Open mlewis-everley opened 9 months ago
That's strange... but I'll take al look :)
Thank you, I have done a little bit more testing my end. It appears this only happens after you run a G29
.
Prior to this, homing works as expected, if I run G28 X
or G28 Y
then the print head moves up 10mm and then performs a home.
After running G29
, the above issues then occur.
Does this bug still exist? I cannot reproduce the error in the current version 1.5.4. :/
Have you read all Wiki articles in cluding the FAQ? YES
Do you want to ask a question? Are you looking for support? Not sure?
Bug Description
I am not sure if this is a bug, or if I have mucked something up in my config, I have installed an inductive probe on my i3 Mega's and they are working perfectly except that now when you issue
G28 X Y
orG28 X
orG28 Y
, the Z axis moves to absolute 5.01 prior to homing the X &/or Y.I cannot see anything obvious in this fork that would cause this behavior. I have added similar features to vanilla marlin for a different printer and am not getting this issue so possibly this is a bug?
Happy to submit a PR for this issue, but at the moment I am stumped as to what might be causing it. I have not used the BLTouch version of this firmware, so not sure if that behaves the same way?
My fork is: https://github.com/mlewis-everley/Marlin-2-0-x-Anycubic-i3-MEGA-S
Steps to Reproduce
G1 Z100
).G28 X Y
.