konnected-io / konnected-security

Konnected connects wired sensors and switches to SmartThings, Home Assistant, Hubitat and OpenHAB
https://konnected.io
Apache License 2.0
416 stars 322 forks source link

ALARM1 e ALARM2 set to LOW when ON #148

Closed errecla closed 3 years ago

errecla commented 3 years ago

Hello. I'm working with Alarm PANEL PRO with 1.2.4 SW Version and 0.1.5-047de6 FW version and Hassio version core-2021.6.5. I need to work with ALARM1 and ALARM2 when on=LOW. My issue is that when I reboot hassio the switches ALARM1 and ALARM2 change status during reboot and siren ringing. Why?

heythisisnate commented 3 years ago

When the device first boots, the outputs of ALARM1 and ALARM2 will momentarily be LOW until the software initializes. This cannot be avoided. It's recommended that you configure your alarm to be ON when the output is HIGH for this reason.

errecla commented 3 years ago

Thanks for your answer but I have a siren that is singing when cut OFF +12V. how can i configure ALARM1 and 2 output in LOW mode? I attach the manual of my siren

2manuale_ENG_SAEL2010_LED_ver_32.pdf

heythisisnate commented 3 years ago

@errecla You may need to use an external relay (controlled by OUT1 or OUT2) to make a normally-closed circuit with 12V+ to the siren input, then when activated it will break that circuit and activate the siren.