Hi,
As the name suggested, the multi-echo phase should be unwrapped in the unwrapped_echo_phase image. I believe there could be some error occurred during the phase unwrapping process.
To better understanding the issue, would you mind providing me the following information:
Kwok
Big Thanks for your kick reply...after cleanning up my MATLAB path, and my project, i did not reproduce the issue. Romain Viard (sorry i sign in with a different account and i do not know how to close the issue)
Good to hear that! I'll close the issue for you.
Great job, SEPIA is well designed, and would be very useful for those who want to come to QSM by customizing their pipeline. Then the documentation with exercices etc..is very interesting.
Yet I tried to reproduce result obtained using MEDI+ with MEDI+ in SEPIA ....but unfortunaltelly I'm far to succeed...so I tired step by step..beginning by phase unwrapping....And I'm wondering why the saved "unwarped_echo_phase" is absolutely identical to the initial phase....(or could be just inverted when "invert phase data" is checked) ...