runmanager is a graphical user interface (GUI) used to aid the compilation of labscript experiment scripts into hardware instructions to be executed on the hardware. Experiment parameters can be adjusted in the GUI, and lists of parameters can be used to create sequences of experiments, and scan over complex parameter spaces.
BSD 2-Clause "Simplified" License
0
stars
0
forks
source link
Abort button only stops current sequence of shots #33
If you click engage to start compiling a sequence of shots across some parameter space, then click again to start a second sequence compiling, then hit abort while the first is still compiling, the second sequence will still be compiled, and the abort button is greyed out so that you cannot abort it.
Original report (archived issue) by Shaun Johnstone (Bitbucket: shjohnst, GitHub: shjohnst).
If you click engage to start compiling a sequence of shots across some parameter space, then click again to start a second sequence compiling, then hit abort while the first is still compiling, the second sequence will still be compiled, and the abort button is greyed out so that you cannot abort it.