Open it-native opened 2 years ago
add -vv | grep "\["
/check_nwc_health --hostname 1.2.3.4 --community "public-what-else" --mode hardware-health -vv | grep "\["
You will get
[DISKSUBSYSTEM]
[DEVICESUBSYSTEM]
[HRDEVICEPROCESSOR_196608]
[HRDEVICENETWORK_lo]
[HRDEVICENETWORK_sit0]
[HRDEVICENETWORK_bond0]
[HRDEVICENETWORK_eth0]
[HRDEVICENETWORK_eth1]
[HRDEVICEPRINTER_327680]
[HRDEVICECOPROCESSOR_786432]
Run: /check_nwc_health --hostname 1.2.3.4 --community "public-what-else" --mode hardware-health --blacklist HRDEVICENETWORK_sit0,HRDEVICENETWORK_bond0
Hi,
what's the correct way to blacklist/whitelist Hardware sensors for mode "hardware-health"? I tries several combinations of --name, --blacklist and --regex but none of them gave blacklistet the powersuppy issue (or only showed temperature, which is also ok)
thx & BR Oliver