lora-aprs / LoRa_APRS_iGate

This is a LoRa APRS iGate/Digi based on an ESP32
https://www.lora-aprs.info
MIT License
331 stars 106 forks source link

Heltec v3 board stuck in boot loop when connected to an USB power supply #331

Closed dm5tt closed 9 months ago

dm5tt commented 9 months ago

Describe the bug After flashing the latest ARPS iGate firmware to a Heltec v3 AND connecting it to an USB power supply only the boot logo shows up and then reboots after a few seconds.

This NOT happens when connected to a PC.

(Cross-checked this with a Meshtastic. This boots up just fine.)

To Reproduce

  1. Flash latest 'master' firmware
  2. Connect device to a USB power supply
  3. Have a look at the screen and wait for reboot

Expected behavior Boot up normally

peterus commented 9 months ago

did you check the power supply if it is producing the 5v correctly? can you try different power supplies? if it is working when connected to pc it will get very hard to debug.

dm5tt commented 9 months ago

I checked with three power supplies and several cables. The Meshtastic firmware on that device seems not to cause any problems.

peterus commented 9 months ago

thanks for your response! will need to check on my end.

dm5tt commented 9 months ago

https://github.com/Heltec-Aaron-Lee/WiFi_Kit_series/issues/159 wild guess, might be related

dm5tt commented 9 months ago

I was able to narrow the problem down: The Heltec v3 is having an incredibly bad Wifi antenna. It was looping during the boot process as it wasn't able to get Wifi on my balcony.