lora-aprs / LoRa_APRS_iGate

This is a LoRa APRS iGate/Digi based on an ESP32
https://www.lora-aprs.info
MIT License
331 stars 106 forks source link

Reboot Loop by usind Calsigns starting with "DN" #337

Closed Retaner closed 8 months ago

Retaner commented 8 months ago

Hello, I tried configuring an Igate with firmware V23.31. With the call sign “DN1KWT” after the boot page I got an upside down message screen very short, for milliseconds, and then the start page with the firmware number. This happens again and again. For example, if I just change it to “DK1KWT”, it works. I tested several combinations with "DN" with the same problem. For me it looks like that there is a problem with the prefix "DN".

Retaner commented 8 months ago

Hello, I found the reason for the problem. I used the alternative server “koblenz.aprs2.net” instead of the default server “euro.aprs2.net”. I had no problems with several different call signs. Only now with the prefix “DN”. After switching to the server “euro.aprs2.net” it now works. I don't know what's wrong with the "Koblenz server", but I have a working system now.