lumapu / ahoy

Various tools, examples, and documentation for communicating with Hoymiles microinverters
https://ahoydtu.de
Other
953 stars 224 forks source link

Neustart wenn man eine weile auf der Serial/Control Seite bleibt: webSerial, buffer overflow! #514

Closed Domain-Markus closed 1 year ago

Domain-Markus commented 1 year ago

Platform

ESP8266

Model name

AZ-Delivery

nRF24L01+ Module

nRF24L01+ plus

Antenna

circuit board

Power Stabilization

~100uF Elko

Connection diagram

Connection diagram I used:

nRF24L01+ Pin ESP8266 GPIO
Pin 1 GND [*] GND
Pin 2 +3.3V +3.3V
Pin 3 CE GPIO2 CE D2
Pin 4 CSN GPIO15 CS D8
Pin 5 SCK GPIO14 SCLK D5
Pin 6 MOSI GPIO13 MOSI D7
Pin 7 MISO GPIO12 MISO D6
Pin 8 IRQ GPIO0 IRQ D1

Note: [*] GND Pin 1 has a square mark on the nRF24L01+ module

Connection picture

Version

0.5.52

Github Hash

67b9170

Build & Flash Method

Platform IO (build & flash)

Desktop

Windows

Setup

Device Host Name

- Device Name: AHOY-DTU

WiFi

- SSID: YOUR_WIFI_SSID *don't paste here*
- Password: YOUR_WIFI_PWD *don't paste here*

Inverter

Inverter 0

- Address: 114181300000
- Name: HM-700 oben
- Active Power Limit: 65535
- Active Power Limit Control Type: no powerlimit
- Max Module Power (Wp): 450, 450
- Module Name: Modul 1, Modul 2

Inverter 1

- Address: 114181300000
- Name: HM-700 mitte
- Active Power Limit: 65535
- Active Power Limit Control Type: no powerlimit
- Max Module Power (Wp): 450, 450
- Module Name: Modul 3, Modul 4

Inverter 2

- Address: 114181300000
- Name: HM-700 unten
- Active Power Limit: 65535
- Active Power Limit Control Type: no powerlimit
- Max Module Power (Wp): 450, 450
- Module Name: Modul 5, Modul 6

General

- Interval [s]: 30
- Max retries per Payload: 5

NTP Server

- NTP Server / IP: pool.ntp.org
- NTP Port: 123

MQTT

- Broker / Server IP: 
- Port: 1883
- Username (optional): 
- Password (optional): 
- Topic: inverter

System Config

Pinout (Wemos)

- CS: D8 (GPIO15)
- CE: D2 (GPIO4)
- IRQ: D1 (GPIO5)

Radio (NRF24L01+)

- Amplifier Power Level: HIGH

Serial Console

- print inverter data: [x]
- Serial Debug: [x]
- Interval [s]: 5

Debug Serial Log output

webSerial, buffer overflow!
12:21:32 I: 
12:21:32 I: Inverter: 2
12:21:32 I: Unten/ch1/U_DC: 42.900 V
12:21:32 I: Unten/ch1/I_DC: 2.740 A
12:21:32 I: Unten/ch1/P_DC: 117.300 W
12:21:32 I: Unten/ch1/YieldDay: 146.000 Wh
12:21:32 I: Unten/ch1/YieldTotal: 2.755 kWh
12:21:32 I: Unten/ch1/Irradiation: 26.067 %
12:21:32 I: Unten/ch2/U_DC: 41.800 V
12:21:32 I: Unten/ch2/I_DC: 2.890 A
12:21:32 I: Unten/ch2/P_DC: 120.500 W
12:21:32 I: Unten/ch2/YieldDay: 181.000 Wh
12:21:32 I: Unten/ch2/YieldTotal: 3.171 kWh
12:21:32 I: Unten/ch2/Irradiation: 26.778 %
12:21:32 I: Unten/ch0/U_AC: 237.500 V
12:21:32 I: Unten/ch0/I_AC: 0.960 A
12:21:32 I: Unten/ch0/P_AC: 227.100 W
12:21:32 I: Unten/ch0/Q_AC: 0.200 var
12:21:32 I: Unten/ch0/F_AC: 49.990 Hz
12:21:32 I: Unten/ch0/PF_AC: 1.000 
12:21:32 I: Unten/ch0/Temp: 19.200 °C
12:21:32 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:21:32 I: Unten/ch0/YieldDay: 327.000 Wh
12:21:32 I: Unten/ch0/YieldTotal: 5.926 kWh
12:21:32 I: Unten/ch0/P_DC: 237.800 W
12:21:32 I: Unten/ch0/Efficiency: 95.500 %
12:21:32 I: 
h1/I_DC: 1.880 A
12:21:32 I: Mitte/ch1/P_DC: 78.000 W
12:21:32 I: Mitte/ch1/YieldDay: 188.000 Wh
12:21:32 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:21:32 I: Mitte/ch1/Irradiation: 17.333 %
12:21:32 I: Mitte/ch2/U_DC: 41.600 V
12:21:32 I: Mitte/ch2/I_DC: 1.780 A
12:21:32 I: Mitte/ch2/P_DC: 73.900 W
12:21:32 I: Mitte/ch2/YieldDay: 186.000 Wh
12:21:32 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:21:32 I: Mitte/ch2/Irradiation: 16.422 %
12:21:32 I: Mitte/ch0/U_AC: 235.100 V
12:21:32 I: Mitte/ch0/I_AC: 0.620 A
12:21:32 I: Mitte/ch0/P_AC: 145.000 W
12:21:32 I: Mitte/ch0/Q_AC: 0.100 var
12:21:32 I: Mitte/ch0/F_AC: 49.980 Hz
12:21:32 I: Mitte/ch0/PF_AC: 1.000 
12:21:32 I: Mitte/ch0/Temp: 16.800 °C
12:21:32 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:21:32 I: Mitte/ch0/YieldDay: 374.000 Wh
12:21:32 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:21:32 I: Mitte/ch0/P_DC: 151.900 W
12:21:32 I: webSerial, buffer overflow!
12:21:36 I: 
12:21:36 I: Inverter: 2
12:21:36 I: Unten/ch1/U_DC: 42.900 V
12:21:36 I: Unten/ch1/I_DC: 2.740 A
12:21:36 I: Unten/ch1/P_DC: 117.300 W
12:21:36 I: Unten/ch1/YieldDay: 146.000 Wh
12:21:36 I: Unten/ch1/YieldTotal: 2.755 kWh
12:21:36 I: Unten/ch1/Irradiation: 26.067 %
12:21:36 I: Unten/ch2/U_DC: 41.800 V
12:21:36 I: Unten/ch2/I_DC: 2.890 A
12:21:36 I: Unten/ch2/P_DC: 120.500 W
12:21:36 I: Unten/ch2/YieldDay: 181.000 Wh
12:21:36 I: Unten/ch2/YieldTotal: 3.171 kWh
12:21:36 I: Unten/ch2/Irradiation: 26.778 %
12:21:36 I: Unten/ch0/U_AC: 237.500 V
12:21:36 I: Unten/ch0/I_AC: 0.960 A
12:21:36 I: Unten/ch0/P_AC: 227.100 W
12:21:36 I: Unten/ch0/Q_AC: 0.200 var
12:21:36 I: Unten/ch0/F_AC: 49.990 Hz
12:21:36 I: Unten/ch0/PF_AC: 1.000 
12:21:36 I: Unten/ch0/Temp: 19.200 °C
12:21:36 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:21:36 I: Unten/ch0/YieldDay: 327.000 Wh
12:21:36 I: Unten/ch0/YieldTotal: 5.926 kWh
12:21:36 I: Unten/ch0/P_DC: 237.800 W
12:21:36 I: Unten/ch0/Efficiency: 95.500 %
12:21:36 I: 
h1/I_DC: 1.880 A
12:21:36 I: Mitte/ch1/P_DC: 78.000 W
12:21:36 I: Mitte/ch1/YieldDay: 188.000 Wh
12:21:36 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:21:36 I: Mitte/ch1/Irradiation: 17.333 %
12:21:36 I: Mitte/ch2/U_DC: 41.600 V
12:21:36 I: Mitte/ch2/I_DC: 1.780 A
12:21:36 I: Mitte/ch2/P_DC: 73.900 W
12:21:36 I: Mitte/ch2/YieldDay: 186.000 Wh
12:21:36 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:21:36 I: Mitte/ch2/Irradiation: 16.422 %
12:21:36 I: Mitte/ch0/U_AC: 235.100 V
12:21:36 I: Mitte/ch0/I_AC: 0.620 A
12:21:36 I: Mitte/ch0/P_AC: 145.000 W
12:21:36 I: Mitte/ch0/Q_AC: 0.100 var
12:21:36 I: Mitte/ch0/F_AC: 49.980 Hz
12:21:36 I: Mitte/ch0/PF_AC: 1.000 
12:21:36 I: Mitte/ch0/Temp: 16.800 °C
12:21:36 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:21:36 I: Mitte/ch0/YieldDay: 374.000 Wh
12:21:36 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:21:36 I: Mitte/ch0/P_DC: 151.900 W
12:21:36 I: webSerial, buffer overflow!
12:21:40 I: 
12:21:40 I: Inverter: 2
12:21:40 I: Unten/ch1/U_DC: 42.900 V
12:21:40 I: Unten/ch1/I_DC: 2.740 A
12:21:40 I: Unten/ch1/P_DC: 117.300 W
12:21:40 I: Unten/ch1/YieldDay: 146.000 Wh
12:21:40 I: Unten/ch1/YieldTotal: 2.755 kWh
12:21:40 I: Unten/ch1/Irradiation: 26.067 %
12:21:40 I: Unten/ch2/U_DC: 41.800 V
12:21:40 I: Unten/ch2/I_DC: 2.890 A
12:21:40 I: Unten/ch2/P_DC: 120.500 W
12:21:40 I: Unten/ch2/YieldDay: 181.000 Wh
12:21:40 I: Unten/ch2/YieldTotal: 3.171 kWh
12:21:40 I: Unten/ch2/Irradiation: 26.778 %
12:21:40 I: Unten/ch0/U_AC: 237.500 V
12:21:40 I: Unten/ch0/I_AC: 0.960 A
12:21:40 I: Unten/ch0/P_AC: 227.100 W
12:21:40 I: Unten/ch0/Q_AC: 0.200 var
12:21:40 I: Unten/ch0/F_AC: 49.990 Hz
12:21:40 I: Unten/ch0/PF_AC: 1.000 
12:21:40 I: Unten/ch0/Temp: 19.200 °C
12:21:40 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:21:40 I: Unten/ch0/YieldDay: 327.000 Wh
12:21:40 I: Unten/ch0/YieldTotal: 5.926 kWh
12:21:40 I: Unten/ch0/P_DC: 237.800 W
12:21:40 I: Unten/ch0/Efficiency: 95.500 %
12:21:40 I: 
h1/I_DC: 1.880 A
12:21:40 I: Mitte/ch1/P_DC: 78.000 W
12:21:40 I: Mitte/ch1/YieldDay: 188.000 Wh
12:21:40 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:21:40 I: Mitte/ch1/Irradiation: 17.333 %
12:21:40 I: Mitte/ch2/U_DC: 41.600 V
12:21:40 I: Mitte/ch2/I_DC: 1.780 A
12:21:40 I: Mitte/ch2/P_DC: 73.900 W
12:21:40 I: Mitte/ch2/YieldDay: 186.000 Wh
12:21:40 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:21:40 I: Mitte/ch2/Irradiation: 16.422 %
12:21:40 I: Mitte/ch0/U_AC: 235.100 V
12:21:40 I: Mitte/ch0/I_AC: 0.620 A
12:21:40 I: Mitte/ch0/P_AC: 145.000 W
12:21:40 I: Mitte/ch0/Q_AC: 0.100 var
12:21:40 I: Mitte/ch0/F_AC: 49.980 Hz
12:21:40 I: Mitte/ch0/PF_AC: 1.000 
12:21:40 I: Mitte/ch0/Temp: 16.800 °C
12:21:40 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:21:40 I: Mitte/ch0/YieldDay: 374.000 Wh
12:21:40 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:21:40 I: Mitte/ch0/P_DC: 151.900 W
12:21:40 I: webSerial, buffer overflow!
12:21:44 I: 
12:21:44 I: Inverter: 2
12:21:44 I: Unten/ch1/U_DC: 42.900 V
12:21:44 I: Unten/ch1/I_DC: 2.740 A
12:21:44 I: Unten/ch1/P_DC: 117.300 W
12:21:44 I: Unten/ch1/YieldDay: 146.000 Wh
12:21:44 I: Unten/ch1/YieldTotal: 2.755 kWh
12:21:44 I: Unten/ch1/Irradiation: 26.067 %
12:21:44 I: Unten/ch2/U_DC: 41.800 V
12:21:44 I: Unten/ch2/I_DC: 2.890 A
12:21:44 I: Unten/ch2/P_DC: 120.500 W
12:21:44 I: Unten/ch2/YieldDay: 181.000 Wh
12:21:44 I: Unten/ch2/YieldTotal: 3.171 kWh
12:21:44 I: Unten/ch2/Irradiation: 26.778 %
12:21:44 I: Unten/ch0/U_AC: 237.500 V
12:21:44 I: Unten/ch0/I_AC: 0.960 A
12:21:44 I: Unten/ch0/P_AC: 227.100 W
12:21:44 I: Unten/ch0/Q_AC: 0.200 var
12:21:44 I: Unten/ch0/F_AC: 49.990 Hz
12:21:44 I: Unten/ch0/PF_AC: 1.000 
12:21:44 I: Unten/ch0/Temp: 19.200 °C
12:21:44 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:21:44 I: Unten/ch0/YieldDay: 327.000 Wh
12:21:44 I: Unten/ch0/YieldTotal: 5.926 kWh
12:21:44 I: Unten/ch0/P_DC: 237.800 W
12:21:44 I: Unten/ch0/Efficiency: 95.500 %
12:21:44 I: 
h1/I_DC: 1.880 A
12:21:44 I: Mitte/ch1/P_DC: 78.000 W
12:21:44 I: Mitte/ch1/YieldDay: 188.000 Wh
12:21:44 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:21:44 I: Mitte/ch1/Irradiation: 17.333 %
12:21:44 I: Mitte/ch2/U_DC: 41.600 V
12:21:44 I: Mitte/ch2/I_DC: 1.780 A
12:21:44 I: Mitte/ch2/P_DC: 73.900 W
12:21:44 I: Mitte/ch2/YieldDay: 186.000 Wh
12:21:44 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:21:44 I: Mitte/ch2/Irradiation: 16.422 %
12:21:44 I: Mitte/ch0/U_AC: 235.100 V
12:21:44 I: Mitte/ch0/I_AC: 0.620 A
12:21:44 I: Mitte/ch0/P_AC: 145.000 W
12:21:44 I: Mitte/ch0/Q_AC: 0.100 var
12:21:44 I: Mitte/ch0/F_AC: 49.980 Hz
12:21:44 I: Mitte/ch0/PF_AC: 1.000 
12:21:44 I: Mitte/ch0/Temp: 16.800 °C
12:21:44 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:21:44 I: Mitte/ch0/YieldDay: 374.000 Wh
12:21:44 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:21:44 I: Mitte/ch0/P_DC: 151.900 W
12:21:44 I: webSerial, buffer overflow!
12:21:48 I: 
12:21:48 I: Inverter: 2
12:21:48 I: Unten/ch1/U_DC: 42.900 V
12:21:48 I: Unten/ch1/I_DC: 2.740 A
12:21:48 I: Unten/ch1/P_DC: 117.300 W
12:21:48 I: Unten/ch1/YieldDay: 146.000 Wh
12:21:48 I: Unten/ch1/YieldTotal: 2.755 kWh
12:21:48 I: Unten/ch1/Irradiation: 26.067 %
12:21:48 I: Unten/ch2/U_DC: 41.800 V
12:21:48 I: Unten/ch2/I_DC: 2.890 A
12:21:48 I: Unten/ch2/P_DC: 120.500 W
12:21:48 I: Unten/ch2/YieldDay: 181.000 Wh
12:21:48 I: Unten/ch2/YieldTotal: 3.171 kWh
12:21:48 I: Unten/ch2/Irradiation: 26.778 %
12:21:48 I: Unten/ch0/U_AC: 237.500 V
12:21:48 I: Unten/ch0/I_AC: 0.960 A
12:21:48 I: Unten/ch0/P_AC: 227.100 W
12:21:48 I: Unten/ch0/Q_AC: 0.200 var
12:21:48 I: Unten/ch0/F_AC: 49.990 Hz
12:21:48 I: Unten/ch0/PF_AC: 1.000 
12:21:48 I: Unten/ch0/Temp: 19.200 °C
12:21:48 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:21:48 I: Unten/ch0/YieldDay: 327.000 Wh
12:21:48 I: Unten/ch0/YieldTotal: 5.926 kWh
12:21:48 I: Unten/ch0/P_DC: 237.800 W
12:21:48 I: Unten/ch0/Efficiency: 95.500 %
12:21:48 I: 
h1/I_DC: 1.880 A
12:21:48 I: Mitte/ch1/P_DC: 78.000 W
12:21:48 I: Mitte/ch1/YieldDay: 188.000 Wh
12:21:48 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:21:48 I: Mitte/ch1/Irradiation: 17.333 %
12:21:48 I: Mitte/ch2/U_DC: 41.600 V
12:21:48 I: Mitte/ch2/I_DC: 1.780 A
12:21:48 I: Mitte/ch2/P_DC: 73.900 W
12:21:48 I: Mitte/ch2/YieldDay: 186.000 Wh
12:21:48 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:21:48 I: Mitte/ch2/Irradiation: 16.422 %
12:21:48 I: Mitte/ch0/U_AC: 235.100 V
12:21:48 I: Mitte/ch0/I_AC: 0.620 A
12:21:48 I: Mitte/ch0/P_AC: 145.000 W
12:21:48 I: Mitte/ch0/Q_AC: 0.100 var
12:21:48 I: Mitte/ch0/F_AC: 49.980 Hz
12:21:48 I: Mitte/ch0/PF_AC: 1.000 
12:21:48 I: Mitte/ch0/Temp: 16.800 °C
12:21:48 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:21:48 I: Mitte/ch0/YieldDay: 374.000 Wh
12:21:48 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:21:48 I: Mitte/ch0/P_DC: 151.900 W
12:21:48 I: webSerial, buffer overflow!
12:21:52 I: 
12:21:52 I: Inverter: 2
12:21:52 I: Unten/ch1/U_DC: 42.900 V
12:21:52 I: Unten/ch1/I_DC: 2.740 A
12:21:52 I: Unten/ch1/P_DC: 117.300 W
12:21:52 I: Unten/ch1/YieldDay: 146.000 Wh
12:21:52 I: Unten/ch1/YieldTotal: 2.755 kWh
12:21:52 I: Unten/ch1/Irradiation: 26.067 %
12:21:52 I: Unten/ch2/U_DC: 41.800 V
12:21:52 I: Unten/ch2/I_DC: 2.890 A
12:21:52 I: Unten/ch2/P_DC: 120.500 W
12:21:52 I: Unten/ch2/YieldDay: 181.000 Wh
12:21:52 I: Unten/ch2/YieldTotal: 3.171 kWh
12:21:52 I: Unten/ch2/Irradiation: 26.778 %
12:21:52 I: Unten/ch0/U_AC: 237.500 V
12:21:52 I: Unten/ch0/I_AC: 0.960 A
12:21:52 I: Unten/ch0/P_AC: 227.100 W
12:21:52 I: Unten/ch0/Q_AC: 0.200 var
12:21:52 I: Unten/ch0/F_AC: 49.990 Hz
12:21:52 I: Unten/ch0/PF_AC: 1.000 
12:21:52 I: Unten/ch0/Temp: 19.200 °C
12:21:52 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:21:52 I: Unten/ch0/YieldDay: 327.000 Wh
12:21:52 I: Unten/ch0/YieldTotal: 5.926 kWh
12:21:52 I: Unten/ch0/P_DC: 237.800 W
12:21:52 I: Unten/ch0/Efficiency: 95.500 %
12:21:52 I: 
h1/I_DC: 1.880 A
12:21:52 I: Mitte/ch1/P_DC: 78.000 W
12:21:52 I: Mitte/ch1/YieldDay: 188.000 Wh
12:21:52 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:21:52 I: Mitte/ch1/Irradiation: 17.333 %
12:21:52 I: Mitte/ch2/U_DC: 41.600 V
12:21:52 I: Mitte/ch2/I_DC: 1.780 A
12:21:52 I: Mitte/ch2/P_DC: 73.900 W
12:21:52 I: Mitte/ch2/YieldDay: 186.000 Wh
12:21:52 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:21:52 I: Mitte/ch2/Irradiation: 16.422 %
12:21:52 I: Mitte/ch0/U_AC: 235.100 V
12:21:52 I: Mitte/ch0/I_AC: 0.620 A
12:21:52 I: Mitte/ch0/P_AC: 145.000 W
12:21:52 I: Mitte/ch0/Q_AC: 0.100 var
12:21:52 I: Mitte/ch0/F_AC: 49.980 Hz
12:21:52 I: Mitte/ch0/PF_AC: 1.000 
12:21:52 I: Mitte/ch0/Temp: 16.800 °C
12:21:52 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:21:52 I: Mitte/ch0/YieldDay: 374.000 Wh
12:21:52 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:21:52 I: Mitte/ch0/P_DC: 151.900 W
12:21:52 I: webSerial, buffer overflow!
12:21:56 I: Mitte/ch0/Temp: 16.800 °C
12:21:56 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:21:56 I: Mitte/ch0/YieldDay: 374.000 Wh
12:21:56 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:21:56 I: Mitte/ch0/P_DC: 151.900 W
12:21:56 I: Mitte/ch0/Efficiency: 95.458 %
12:21:56 I: 
12:21:56 I: Inverter: 2
12:21:56 I: Unten/ch1/U_DC: 42.900 V
12:21:56 I: Unten/ch1/I_DC: 2.740 A
12:21:56 I: Unten/ch1/P_DC: 117.300 W
12:21:56 I: Unten/ch1/YieldDay: 146.000 Wh
12:21:56 I: Unten/ch1/YieldTotal: 2.755 kWh
12:21:56 I: Unten/ch1/Irradiation: 26.067 %
12:21:56 I: Unten/ch2/U_DC: 41.800 V
12:21:56 I: Unten/ch2/I_DC: 2.890 A
12:21:56 I: Unten/ch2/P_DC: 120.500 W
12:21:56 I: Unten/ch2/YieldDay: 181.000 Wh
12:21:56 I: Unten/ch2/YieldTotal: 3.171 kWh
12:21:56 I: Unten/ch2/Irradiation: 26.778 %
12:21:56 I: Unten/ch0/U_AC: 237.500 V
12:21:56 I: Unten/ch0/I_AC: 0.960 A
12:21:56 I: Unten/ch0/P_AC: 227.100 W
12:21:56 I: Unten/ch0/Q_AC: 0.200 var
12:21:56 I: Unten/ch0/F_AC: 49.990 Hz
12:21:56 I: Unten/ch0/PF_AC: 1.000 
12:21:56 I: Unten/ch0/Temp: 19.200 °C
12:21:56 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:21:56 I: Unten/ch0/YieldDay: 327.000 Wh
12:21:56 I: Unten/ch0/YieldTotal: 5.926 kWh
12:21:56 I: Unten/ch0/P_DC: 237.800 W
12:21:56 I: Unten/ch0/Efficiency: 95.500 %
12:21:56 I: 
12:21:56 I: RX 27B Ch3 | 95 81 30 32 89 81 30 32 89 01 00 01 01 b0 00 a0 02 b1 01 9c 00 b5 02 ea 00 00 f7 
12:21:56 I: RX 27B Ch3 | 95 81 30 32 89 81 30 32 89 01 00 01 01 b0 00 a0 02 b1 01 9c 00 b5 02 ea 00 00 f7 
12:21:56 I: RX 27B Ch3 | 95 81 30 32 89 81 30 32 89 01 00 01 01 b0 00 a0 02 b1 01 9c 00 b5 02 ea 00 00 f7 
 Mitte/ch2/YieldDay: 186.000 Wh
12:21:56 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:21:56 I: Mitte/ch2/Irradiation: 16.422 %
12:21:56 I: Mitte/ch0/U_AC: 235.100 V
12:21:56 I: Mitte/ch0/I_AC: 0.620 A
12:21:56 I: Mitte/ch0/P_AC: 145.000 W
12:21:56 I: Mitte/ch0/Q_AC: 0.100 var
12:21:56 I: Mitte/ch0/F_AC: 49.980 Hz
12:21:56 I: 12:21:57 W: while retrieving data: last frame missing: Request Retransmit
12:21:57 I: TX 11B Ch40 | 15 81 30 32 89 84 10 66 54 83 3a 
12:21:57 I: RX 23B Ch3 | 95 81 30 32 89 81 30 32 89 83 00 00 00 3a 03 e8 00 c3 00 01 ec 47 ae 
12:21:58 W: while retrieving data: Frame 2 missing: Request Retransmit
12:21:58 I: TX 11B Ch61 | 15 81 30 32 89 84 10 66 54 82 3b 
12:21:58 I: RX 27B Ch3 | 95 81 30 32 89 81 30 32 89 02 0a ca 00 00 0c 6a 00 99 00 bc 09 49 13 87 05 5b 9e 
12:21:58 I: RX 27B Ch3 | 95 81 30 32 89 81 30 32 89 02 0a ca 00 00 0c 6a 00 99 00 bc 09 49 13 87 05 5b 9e 
12:21:58 I: RX 27B Ch23 | 95 81 30 32 89 81 30 32 89 02 0a ca 00 00 0c 6a 00 99 00 bc 09 49 13 87 05 5b 9e 
12:21:58 I: procPyld: cmd:  11
12:21:58 I: procPyld: txid: 0x95
12:21:58 I: Payload (42): 00 01 01 b0 00 a0 02 b1 01 9c 00 b5 02 ea 00 00 0a ca 00 00 0c 6a 00 99 00 bc 09 49 13 87 05 5b 00 00 00 3a 03 e8 00 c3 00 01 
webSerial, buffer overflow!
12:22:00 I: 
12:22:00 I: Inverter: 2
12:22:00 I: Unten/ch1/U_DC: 43.200 V
12:22:00 I: Unten/ch1/I_DC: 1.600 A
12:22:00 I: Unten/ch1/P_DC: 68.900 W
12:22:00 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:00 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:00 I: Unten/ch1/Irradiation: 15.311 %
12:22:00 I: Unten/ch2/U_DC: 41.200 V
12:22:00 I: Unten/ch2/I_DC: 1.810 A
12:22:00 I: Unten/ch2/P_DC: 74.600 W
12:22:00 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:00 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:00 I: Unten/ch2/Irradiation: 16.578 %
12:22:00 I: Unten/ch0/U_AC: 237.700 V
12:22:00 I: Unten/ch0/I_AC: 0.580 A
12:22:00 I: Unten/ch0/P_AC: 137.100 W
12:22:00 I: Unten/ch0/F_AC: 49.990 Hz
12:22:00 I: Unten/ch0/PF_AC: 1.000 
12:22:00 I: Unten/ch0/Temp: 19.500 °C
12:22:00 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:00 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:00 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:00 I: Unten/ch0/P_DC: 143.500 W
12:22:00 I: Unten/ch0/Efficiency: 95.540 %
12:22:00 I: 
e/ch1/U_DC: 41.400 V
12:22:00 I: Mitte/ch1/I_DC: 1.880 A
12:22:00 I: Mitte/ch1/P_DC: 78.000 W
12:22:00 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:00 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:00 I: Mitte/ch1/Irradiation: 17.333 %
12:22:00 I: Mitte/ch2/U_DC: 41.600 V
12:22:00 I: Mitte/ch2/I_DC: 1.780 A
12:22:00 I: Mitte/ch2/P_DC: 73.900 W
12:22:00 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:00 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:00 I: Mitte/ch2/Irradiation: 16.422 %
12:22:00 I: Mitte/ch0/U_AC: 235.100 V
12:22:00 I: Mitte/ch0/I_AC: 0.620 A
12:22:00 I: Mitte/ch0/P_AC: 145.000 W
12:22:00 I: Mitte/ch0/Q_AC: 0.100 var
12:22:00 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:00 I: Mitte/ch0/PF_AC: 1.000 
12:22:00 I: Mitte/ch0/Temp: 16.800 °C
12:22:00 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:00 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:00 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:00 I: Mitte/ch0/P_DC: 151.900 W
12:22:00 I: webSerial, buffer overflow!
12:22:04 I: 
12:22:04 I: Inverter: 2
12:22:04 I: Unten/ch1/U_DC: 43.200 V
12:22:04 I: Unten/ch1/I_DC: 1.600 A
12:22:04 I: Unten/ch1/P_DC: 68.900 W
12:22:04 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:04 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:04 I: Unten/ch1/Irradiation: 15.311 %
12:22:04 I: Unten/ch2/U_DC: 41.200 V
12:22:04 I: Unten/ch2/I_DC: 1.810 A
12:22:04 I: Unten/ch2/P_DC: 74.600 W
12:22:04 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:04 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:04 I: Unten/ch2/Irradiation: 16.578 %
12:22:04 I: Unten/ch0/U_AC: 237.700 V
12:22:04 I: Unten/ch0/I_AC: 0.580 A
12:22:04 I: Unten/ch0/P_AC: 137.100 W
12:22:04 I: Unten/ch0/F_AC: 49.990 Hz
12:22:04 I: Unten/ch0/PF_AC: 1.000 
12:22:04 I: Unten/ch0/Temp: 19.500 °C
12:22:04 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:04 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:04 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:04 I: Unten/ch0/P_DC: 143.500 W
12:22:04 I: Unten/ch0/Efficiency: 95.540 %
12:22:04 I: 
e/ch1/U_DC: 41.400 V
12:22:04 I: Mitte/ch1/I_DC: 1.880 A
12:22:04 I: Mitte/ch1/P_DC: 78.000 W
12:22:04 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:04 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:04 I: Mitte/ch1/Irradiation: 17.333 %
12:22:04 I: Mitte/ch2/U_DC: 41.600 V
12:22:04 I: Mitte/ch2/I_DC: 1.780 A
12:22:04 I: Mitte/ch2/P_DC: 73.900 W
12:22:04 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:04 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:04 I: Mitte/ch2/Irradiation: 16.422 %
12:22:04 I: Mitte/ch0/U_AC: 235.100 V
12:22:04 I: Mitte/ch0/I_AC: 0.620 A
12:22:04 I: Mitte/ch0/P_AC: 145.000 W
12:22:04 I: Mitte/ch0/Q_AC: 0.100 var
12:22:04 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:04 I: Mitte/ch0/PF_AC: 1.000 
12:22:04 I: Mitte/ch0/Temp: 16.800 °C
12:22:04 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:04 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:04 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:04 I: Mitte/ch0/P_DC: 151.900 W
12:22:04 I: webSerial, buffer overflow!webSerial, buffer overflow!
12:22:20 I: 
12:22:20 I: Inverter: 2
12:22:20 I: Unten/ch1/U_DC: 43.200 V
12:22:20 I: Unten/ch1/I_DC: 1.600 A
12:22:20 I: Unten/ch1/P_DC: 68.900 W
12:22:20 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:20 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:20 I: Unten/ch1/Irradiation: 15.311 %
12:22:20 I: Unten/ch2/U_DC: 41.200 V
12:22:20 I: Unten/ch2/I_DC: 1.810 A
12:22:20 I: Unten/ch2/P_DC: 74.600 W
12:22:20 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:20 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:20 I: Unten/ch2/Irradiation: 16.578 %
12:22:20 I: Unten/ch0/U_AC: 237.700 V
12:22:20 I: Unten/ch0/I_AC: 0.580 A
12:22:20 I: Unten/ch0/P_AC: 137.100 W
12:22:20 I: Unten/ch0/F_AC: 49.990 Hz
12:22:20 I: Unten/ch0/PF_AC: 1.000 
12:22:20 I: Unten/ch0/Temp: 19.500 °C
12:22:20 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:20 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:20 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:20 I: Unten/ch0/P_DC: 143.500 W
12:22:20 I: Unten/ch0/Efficiency: 95.540 %
12:22:20 I: 
e/ch1/U_DC: 41.400 V
12:22:20 I: Mitte/ch1/I_DC: 1.880 A
12:22:20 I: Mitte/ch1/P_DC: 78.000 W
12:22:20 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:20 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:20 I: Mitte/ch1/Irradiation: 17.333 %
12:22:20 I: Mitte/ch2/U_DC: 41.600 V
12:22:20 I: Mitte/ch2/I_DC: 1.780 A
12:22:20 I: Mitte/ch2/P_DC: 73.900 W
12:22:20 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:20 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:20 I: Mitte/ch2/Irradiation: 16.422 %
12:22:20 I: Mitte/ch0/U_AC: 235.100 V
12:22:20 I: Mitte/ch0/I_AC: 0.620 A
12:22:20 I: Mitte/ch0/P_AC: 145.000 W
12:22:20 I: Mitte/ch0/Q_AC: 0.100 var
12:22:20 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:20 I: Mitte/ch0/PF_AC: 1.000 
12:22:20 I: Mitte/ch0/Temp: 16.800 °C
12:22:20 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:20 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:20 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:20 I: Mitte/ch0/P_DC: 151.900 W
12:22:20 I: webSerial, buffer overflow!
12:22:24 I: 
12:22:24 I: Inverter: 2
12:22:24 I: Unten/ch1/U_DC: 43.200 V
12:22:24 I: Unten/ch1/I_DC: 1.600 A
12:22:24 I: Unten/ch1/P_DC: 68.900 W
12:22:24 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:24 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:24 I: Unten/ch1/Irradiation: 15.311 %
12:22:24 I: Unten/ch2/U_DC: 41.200 V
12:22:24 I: Unten/ch2/I_DC: 1.810 A
12:22:24 I: Unten/ch2/P_DC: 74.600 W
12:22:24 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:24 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:24 I: Unten/ch2/Irradiation: 16.578 %
12:22:24 I: Unten/ch0/U_AC: 237.700 V
12:22:24 I: Unten/ch0/I_AC: 0.580 A
12:22:24 I: Unten/ch0/P_AC: 137.100 W
12:22:24 I: Unten/ch0/F_AC: 49.990 Hz
12:22:24 I: Unten/ch0/PF_AC: 1.000 
12:22:24 I: Unten/ch0/Temp: 19.500 °C
12:22:24 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:24 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:24 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:24 I: Unten/ch0/P_DC: 143.500 W
12:22:24 I: Unten/ch0/Efficiency: 95.540 %
12:22:24 I: 
e/ch1/U_DC: 41.400 V
12:22:24 I: Mitte/ch1/I_DC: 1.880 A
12:22:24 I: Mitte/ch1/P_DC: 78.000 W
12:22:24 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:24 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:24 I: Mitte/ch1/Irradiation: 17.333 %
12:22:24 I: Mitte/ch2/U_DC: 41.600 V
12:22:24 I: Mitte/ch2/I_DC: 1.780 A
12:22:24 I: Mitte/ch2/P_DC: 73.900 W
12:22:24 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:24 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:24 I: Mitte/ch2/Irradiation: 16.422 %
12:22:24 I: Mitte/ch0/U_AC: 235.100 V
12:22:24 I: Mitte/ch0/I_AC: 0.620 A
12:22:24 I: Mitte/ch0/P_AC: 145.000 W
12:22:24 I: Mitte/ch0/Q_AC: 0.100 var
12:22:24 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:24 I: Mitte/ch0/PF_AC: 1.000 
12:22:24 I: Mitte/ch0/Temp: 16.800 °C
12:22:24 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:24 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:24 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:24 I: Mitte/ch0/P_DC: 151.900 W
12:22:24 I: 12:22:25 I: resetPayload: id: 0
12:22:25 I: (#0) Requesting Inv SN 114181300000
12:22:25 I: (#0) enqueuedCmd: 11
12:22:25 I: (#0) sendTimePacket
12:22:25 I: TX 27B Ch75 | 15 81 30 29 73 84 10 66 54 80 0b 00 63 a1 9a f1 00 00 00 01 00 00 00 00 b9 31 f3 
12:22:25 I: RX 27B Ch3 | 95 81 30 29 73 81 30 29 73 01 00 01 01 ad 00 78 02 04 01 a0 00 73 01 e0 00 00 74 
12:22:25 I: RX 27B Ch23 | 95 81 30 29 73 81 30 29 73 01 00 01 01 ad 00 78 02 04 01 a0 00 73 01 e0 00 00 74 
12:22:25 I: RX 23B Ch3 | 95 81 30 29 73 81 30 29 73 83 00 00 00 28 03 e8 00 90 00 01 cc b3 3b 
12:22:25 I: RX 23B Ch23 | 95 81 30 29 73 81 30 29 73 83 00 00 00 28 03 e8 00 90 00 01 cc b3 3b 
12:22:26 W: while retrieving data: Frame 2 missing: Request Retransmit
12:22:26 I: TX 11B Ch3 | 15 81 30 29 73 84 10 66 54 82 da 
12:22:26 I: RX 27B Ch3 | 95 81 30 29 73 81 30 29 73 02 08 b7 00 00 08 cd 00 a5 00 82 09 4a 13 87 03 b7 a9 
12:22:26 I: RX 27B Ch23 | 95 81 30 29 73 81 30 29 73 02 08 b7 00 00 08 cd 00 a5 00 82 09 4a 13 87 03 b7 a9 
12:22:26 I: RX 27B Ch23 | 95 81 30 29 73 81 30 29 73 02 08 b7 00 00 08 cd 00 a5 00 82 09 4a 13 87 03 b7 a9 
12:22:27 I: procPyld: cmd:  11
12:22:27 I: procPyld: txid: 0x95
12:22:27 I: Payload (42): 00 01 01 ad 00 78 02 04 01 a0 00 73 01 e0 00 00 08 b7 00 00 08 cd 00 a5 00 82 09 4a 13 87 03 b7 00 00 00 28 03 e8 00 90 00 01 
webSerial, buffer overflow!
12:22:28 I: 
12:22:28 I: Inverter: 2
12:22:28 I: Unten/ch1/U_DC: 43.200 V
12:22:28 I: Unten/ch1/I_DC: 1.600 A
12:22:28 I: Unten/ch1/P_DC: 68.900 W
12:22:28 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:28 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:28 I: Unten/ch1/Irradiation: 15.311 %
12:22:28 I: Unten/ch2/U_DC: 41.200 V
12:22:28 I: Unten/ch2/I_DC: 1.810 A
12:22:28 I: Unten/ch2/P_DC: 74.600 W
12:22:28 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:28 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:28 I: Unten/ch2/Irradiation: 16.578 %
12:22:28 I: Unten/ch0/U_AC: 237.700 V
12:22:28 I: Unten/ch0/I_AC: 0.580 A
12:22:28 I: Unten/ch0/P_AC: 137.100 W
12:22:28 I: Unten/ch0/F_AC: 49.990 Hz
12:22:28 I: Unten/ch0/PF_AC: 1.000 
12:22:28 I: Unten/ch0/Temp: 19.500 °C
12:22:28 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:28 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:28 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:28 I: Unten/ch0/P_DC: 143.500 W
12:22:28 I: Unten/ch0/Efficiency: 95.540 %
12:22:28 I: 
ch1/U_DC: 41.400 V
12:22:28 I: Mitte/ch1/I_DC: 1.880 A
12:22:28 I: Mitte/ch1/P_DC: 78.000 W
12:22:28 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:28 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:28 I: Mitte/ch1/Irradiation: 17.333 %
12:22:28 I: Mitte/ch2/U_DC: 41.600 V
12:22:28 I: Mitte/ch2/I_DC: 1.780 A
12:22:28 I: Mitte/ch2/P_DC: 73.900 W
12:22:28 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:28 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:28 I: Mitte/ch2/Irradiation: 16.422 %
12:22:28 I: Mitte/ch0/U_AC: 235.100 V
12:22:28 I: Mitte/ch0/I_AC: 0.620 A
12:22:28 I: Mitte/ch0/P_AC: 145.000 W
12:22:28 I: Mitte/ch0/Q_AC: 0.100 var
12:22:28 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:28 I: Mitte/ch0/PF_AC: 1.000 
12:22:28 I: Mitte/ch0/Temp: 16.800 °C
12:22:28 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:28 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:28 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:28 I: Mitte/ch0/P_DC: 151.900 W
12:22:28 I: webSerial, buffer overflow!
12:22:32 I: 
12:22:32 I: Inverter: 2
12:22:32 I: Unten/ch1/U_DC: 43.200 V
12:22:32 I: Unten/ch1/I_DC: 1.600 A
12:22:32 I: Unten/ch1/P_DC: 68.900 W
12:22:32 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:32 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:32 I: Unten/ch1/Irradiation: 15.311 %
12:22:32 I: Unten/ch2/U_DC: 41.200 V
12:22:32 I: Unten/ch2/I_DC: 1.810 A
12:22:32 I: Unten/ch2/P_DC: 74.600 W
12:22:32 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:32 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:32 I: Unten/ch2/Irradiation: 16.578 %
12:22:32 I: Unten/ch0/U_AC: 237.700 V
12:22:32 I: Unten/ch0/I_AC: 0.580 A
12:22:32 I: Unten/ch0/P_AC: 137.100 W
12:22:32 I: Unten/ch0/F_AC: 49.990 Hz
12:22:32 I: Unten/ch0/PF_AC: 1.000 
12:22:32 I: Unten/ch0/Temp: 19.500 °C
12:22:32 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:32 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:32 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:32 I: Unten/ch0/P_DC: 143.500 W
12:22:32 I: Unten/ch0/Efficiency: 95.540 %
12:22:32 I: 
ch1/U_DC: 41.400 V
12:22:32 I: Mitte/ch1/I_DC: 1.880 A
12:22:32 I: Mitte/ch1/P_DC: 78.000 W
12:22:32 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:32 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:32 I: Mitte/ch1/Irradiation: 17.333 %
12:22:32 I: Mitte/ch2/U_DC: 41.600 V
12:22:32 I: Mitte/ch2/I_DC: 1.780 A
12:22:32 I: Mitte/ch2/P_DC: 73.900 W
12:22:32 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:32 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:32 I: Mitte/ch2/Irradiation: 16.422 %
12:22:32 I: Mitte/ch0/U_AC: 235.100 V
12:22:32 I: Mitte/ch0/I_AC: 0.620 A
12:22:32 I: Mitte/ch0/P_AC: 145.000 W
12:22:32 I: Mitte/ch0/Q_AC: 0.100 var
12:22:32 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:32 I: Mitte/ch0/PF_AC: 1.000 
12:22:32 I: Mitte/ch0/Temp: 16.800 °C
12:22:32 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:32 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:32 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:32 I: Mitte/ch0/P_DC: 151.900 W
12:22:32 I: webSerial, buffer overflow!
12:22:36 I: 
12:22:36 I: Inverter: 2
12:22:36 I: Unten/ch1/U_DC: 43.200 V
12:22:36 I: Unten/ch1/I_DC: 1.600 A
12:22:36 I: Unten/ch1/P_DC: 68.900 W
12:22:36 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:36 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:36 I: Unten/ch1/Irradiation: 15.311 %
12:22:36 I: Unten/ch2/U_DC: 41.200 V
12:22:36 I: Unten/ch2/I_DC: 1.810 A
12:22:36 I: Unten/ch2/P_DC: 74.600 W
12:22:36 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:36 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:36 I: Unten/ch2/Irradiation: 16.578 %
12:22:36 I: Unten/ch0/U_AC: 237.700 V
12:22:36 I: Unten/ch0/I_AC: 0.580 A
12:22:36 I: Unten/ch0/P_AC: 137.100 W
12:22:36 I: Unten/ch0/F_AC: 49.990 Hz
12:22:36 I: Unten/ch0/PF_AC: 1.000 
12:22:36 I: Unten/ch0/Temp: 19.500 °C
12:22:36 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:36 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:36 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:36 I: Unten/ch0/P_DC: 143.500 W
12:22:36 I: Unten/ch0/Efficiency: 95.540 %
12:22:36 I: 
ch1/U_DC: 41.400 V
12:22:36 I: Mitte/ch1/I_DC: 1.880 A
12:22:36 I: Mitte/ch1/P_DC: 78.000 W
12:22:36 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:36 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:36 I: Mitte/ch1/Irradiation: 17.333 %
12:22:36 I: Mitte/ch2/U_DC: 41.600 V
12:22:36 I: Mitte/ch2/I_DC: 1.780 A
12:22:36 I: Mitte/ch2/P_DC: 73.900 W
12:22:36 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:36 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:36 I: Mitte/ch2/Irradiation: 16.422 %
12:22:36 I: Mitte/ch0/U_AC: 235.100 V
12:22:36 I: Mitte/ch0/I_AC: 0.620 A
12:22:36 I: Mitte/ch0/P_AC: 145.000 W
12:22:36 I: Mitte/ch0/Q_AC: 0.100 var
12:22:36 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:36 I: Mitte/ch0/PF_AC: 1.000 
12:22:36 I: Mitte/ch0/Temp: 16.800 °C
12:22:36 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:36 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:36 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:36 I: Mitte/ch0/P_DC: 151.900 W
12:22:36 I: webSerial, buffer overflow!
12:22:40 I: 
12:22:40 I: Inverter: 2
12:22:40 I: Unten/ch1/U_DC: 43.200 V
12:22:40 I: Unten/ch1/I_DC: 1.600 A
12:22:40 I: Unten/ch1/P_DC: 68.900 W
12:22:40 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:40 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:40 I: Unten/ch1/Irradiation: 15.311 %
12:22:40 I: Unten/ch2/U_DC: 41.200 V
12:22:40 I: Unten/ch2/I_DC: 1.810 A
12:22:40 I: Unten/ch2/P_DC: 74.600 W
12:22:40 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:40 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:40 I: Unten/ch2/Irradiation: 16.578 %
12:22:40 I: Unten/ch0/U_AC: 237.700 V
12:22:40 I: Unten/ch0/I_AC: 0.580 A
12:22:40 I: Unten/ch0/P_AC: 137.100 W
12:22:40 I: Unten/ch0/F_AC: 49.990 Hz
12:22:40 I: Unten/ch0/PF_AC: 1.000 
12:22:40 I: Unten/ch0/Temp: 19.500 °C
12:22:40 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:40 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:40 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:40 I: Unten/ch0/P_DC: 143.500 W
12:22:40 I: Unten/ch0/Efficiency: 95.540 %
12:22:40 I: 
ch1/U_DC: 41.400 V
12:22:40 I: Mitte/ch1/I_DC: 1.880 A
12:22:40 I: Mitte/ch1/P_DC: 78.000 W
12:22:40 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:40 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:40 I: Mitte/ch1/Irradiation: 17.333 %
12:22:40 I: Mitte/ch2/U_DC: 41.600 V
12:22:40 I: Mitte/ch2/I_DC: 1.780 A
12:22:40 I: Mitte/ch2/P_DC: 73.900 W
12:22:40 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:40 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:40 I: Mitte/ch2/Irradiation: 16.422 %
12:22:40 I: Mitte/ch0/U_AC: 235.100 V
12:22:40 I: Mitte/ch0/I_AC: 0.620 A
12:22:40 I: Mitte/ch0/P_AC: 145.000 W
12:22:40 I: Mitte/ch0/Q_AC: 0.100 var
12:22:40 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:40 I: Mitte/ch0/PF_AC: 1.000 
12:22:40 I: Mitte/ch0/Temp: 16.800 °C
12:22:40 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:40 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:40 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:40 I: Mitte/ch0/P_DC: 151.900 W
12:22:40 I: webSerial, buffer overflow!
12:22:44 I: 
12:22:44 I: Inverter: 2
12:22:44 I: Unten/ch1/U_DC: 43.200 V
12:22:44 I: Unten/ch1/I_DC: 1.600 A
12:22:44 I: Unten/ch1/P_DC: 68.900 W
12:22:44 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:44 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:44 I: Unten/ch1/Irradiation: 15.311 %
12:22:44 I: Unten/ch2/U_DC: 41.200 V
12:22:44 I: Unten/ch2/I_DC: 1.810 A
12:22:44 I: Unten/ch2/P_DC: 74.600 W
12:22:44 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:44 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:44 I: Unten/ch2/Irradiation: 16.578 %
12:22:44 I: Unten/ch0/U_AC: 237.700 V
12:22:44 I: Unten/ch0/I_AC: 0.580 A
12:22:44 I: Unten/ch0/P_AC: 137.100 W
12:22:44 I: Unten/ch0/F_AC: 49.990 Hz
12:22:44 I: Unten/ch0/PF_AC: 1.000 
12:22:44 I: Unten/ch0/Temp: 19.500 °C
12:22:44 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:44 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:44 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:44 I: Unten/ch0/P_DC: 143.500 W
12:22:44 I: Unten/ch0/Efficiency: 95.540 %
12:22:44 I: 
ch1/U_DC: 41.400 V
12:22:44 I: Mitte/ch1/I_DC: 1.880 A
12:22:44 I: Mitte/ch1/P_DC: 78.000 W
12:22:44 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:44 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:44 I: Mitte/ch1/Irradiation: 17.333 %
12:22:44 I: Mitte/ch2/U_DC: 41.600 V
12:22:44 I: Mitte/ch2/I_DC: 1.780 A
12:22:44 I: Mitte/ch2/P_DC: 73.900 W
12:22:44 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:44 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:44 I: Mitte/ch2/Irradiation: 16.422 %
12:22:44 I: Mitte/ch0/U_AC: 235.100 V
12:22:44 I: Mitte/ch0/I_AC: 0.620 A
12:22:44 I: Mitte/ch0/P_AC: 145.000 W
12:22:44 I: Mitte/ch0/Q_AC: 0.100 var
12:22:44 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:44 I: Mitte/ch0/PF_AC: 1.000 
12:22:44 I: Mitte/ch0/Temp: 16.800 °C
12:22:44 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:44 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:44 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:44 I: Mitte/ch0/P_DC: 151.900 W
12:22:44 I: webSerial, buffer overflow!
12:22:48 I: 
12:22:48 I: Inverter: 2
12:22:48 I: Unten/ch1/U_DC: 43.200 V
12:22:48 I: Unten/ch1/I_DC: 1.600 A
12:22:48 I: Unten/ch1/P_DC: 68.900 W
12:22:48 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:48 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:48 I: Unten/ch1/Irradiation: 15.311 %
12:22:48 I: Unten/ch2/U_DC: 41.200 V
12:22:48 I: Unten/ch2/I_DC: 1.810 A
12:22:48 I: Unten/ch2/P_DC: 74.600 W
12:22:48 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:48 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:48 I: Unten/ch2/Irradiation: 16.578 %
12:22:48 I: Unten/ch0/U_AC: 237.700 V
12:22:48 I: Unten/ch0/I_AC: 0.580 A
12:22:48 I: Unten/ch0/P_AC: 137.100 W
12:22:48 I: Unten/ch0/F_AC: 49.990 Hz
12:22:48 I: Unten/ch0/PF_AC: 1.000 
12:22:48 I: Unten/ch0/Temp: 19.500 °C
12:22:48 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:48 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:48 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:48 I: Unten/ch0/P_DC: 143.500 W
12:22:48 I: Unten/ch0/Efficiency: 95.540 %
12:22:48 I: 
ch1/U_DC: 41.400 V
12:22:48 I: Mitte/ch1/I_DC: 1.880 A
12:22:48 I: Mitte/ch1/P_DC: 78.000 W
12:22:48 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:48 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:48 I: Mitte/ch1/Irradiation: 17.333 %
12:22:48 I: Mitte/ch2/U_DC: 41.600 V
12:22:48 I: Mitte/ch2/I_DC: 1.780 A
12:22:48 I: Mitte/ch2/P_DC: 73.900 W
12:22:48 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:48 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:48 I: Mitte/ch2/Irradiation: 16.422 %
12:22:48 I: Mitte/ch0/U_AC: 235.100 V
12:22:48 I: Mitte/ch0/I_AC: 0.620 A
12:22:48 I: Mitte/ch0/P_AC: 145.000 W
12:22:48 I: Mitte/ch0/Q_AC: 0.100 var
12:22:48 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:48 I: Mitte/ch0/PF_AC: 1.000 
12:22:48 I: Mitte/ch0/Temp: 16.800 °C
12:22:48 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:48 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:48 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:48 I: Mitte/ch0/P_DC: 151.900 W
12:22:48 I: webSerial, buffer overflow!
12:22:52 I: 
12:22:52 I: Inverter: 2
12:22:52 I: Unten/ch1/U_DC: 43.200 V
12:22:52 I: Unten/ch1/I_DC: 1.600 A
12:22:52 I: Unten/ch1/P_DC: 68.900 W
12:22:52 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:52 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:52 I: Unten/ch1/Irradiation: 15.311 %
12:22:52 I: Unten/ch2/U_DC: 41.200 V
12:22:52 I: Unten/ch2/I_DC: 1.810 A
12:22:52 I: Unten/ch2/P_DC: 74.600 W
12:22:52 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:52 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:52 I: Unten/ch2/Irradiation: 16.578 %
12:22:52 I: Unten/ch0/U_AC: 237.700 V
12:22:52 I: Unten/ch0/I_AC: 0.580 A
12:22:52 I: Unten/ch0/P_AC: 137.100 W
12:22:52 I: Unten/ch0/F_AC: 49.990 Hz
12:22:52 I: Unten/ch0/PF_AC: 1.000 
12:22:52 I: Unten/ch0/Temp: 19.500 °C
12:22:52 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:52 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:52 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:52 I: Unten/ch0/P_DC: 143.500 W
12:22:52 I: Unten/ch0/Efficiency: 95.540 %
12:22:52 I: 
ch1/U_DC: 41.400 V
12:22:52 I: Mitte/ch1/I_DC: 1.880 A
12:22:52 I: Mitte/ch1/P_DC: 78.000 W
12:22:52 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:52 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:52 I: Mitte/ch1/Irradiation: 17.333 %
12:22:52 I: Mitte/ch2/U_DC: 41.600 V
12:22:52 I: Mitte/ch2/I_DC: 1.780 A
12:22:52 I: Mitte/ch2/P_DC: 73.900 W
12:22:52 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:52 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:52 I: Mitte/ch2/Irradiation: 16.422 %
12:22:52 I: Mitte/ch0/U_AC: 235.100 V
12:22:52 I: Mitte/ch0/I_AC: 0.620 A
12:22:52 I: Mitte/ch0/P_AC: 145.000 W
12:22:52 I: Mitte/ch0/Q_AC: 0.100 var
12:22:52 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:52 I: Mitte/ch0/PF_AC: 1.000 
12:22:52 I: Mitte/ch0/Temp: 16.800 °C
12:22:52 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:52 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:52 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:52 I: Mitte/ch0/P_DC: 151.900 W
12:22:52 I: 12:22:54 I: resetPayload: id: 1
12:22:54 I: (#1) Requesting Inv SN 114181300000
12:22:54 I: (#1) enqueuedCmd: 11
12:22:54 I: (#1) sendTimePacket
12:22:54 I: TX 27B Ch23 | 15 81 30 49 61 84 10 66 54 80 0b 00 63 a1 9b 0e 00 00 00 01 00 00 00 00 88 25 5a 
12:22:54 I: RX 27B Ch3 | 95 81 30 49 61 81 30 49 61 01 00 01 01 a4 01 0f 04 72 01 b5 00 e6 03 ed 00 00 f4 
12:22:54 I: RX 27B Ch23 | 95 81 30 49 61 81 30 49 61 01 00 01 01 a4 01 0f 04 72 01 b5 00 e6 03 ed 00 00 f4 
12:22:54 I: RX 23B Ch3 | 95 81 30 49 61 81 30 49 61 83 00 00 00 57 03 e8 00 a8 00 01 75 3b 4d 
webSerial, buffer overflow!
12:22:56 I: Mitte/ch0/F_AC: 49.980 Hz
12:22:56 I: Mitte/ch0/PF_AC: 1.000 
12:22:56 I: Mitte/ch0/Temp: 16.800 °C
12:22:56 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:22:56 I: Mitte/ch0/YieldDay: 374.000 Wh
12:22:56 I: Mitte/ch0/YieldTotal: 5.318 kWh
12:22:56 I: Mitte/ch0/P_DC: 151.900 W
12:22:56 I: Mitte/ch0/Efficiency: 95.458 %
12:22:56 I: 
12:22:56 I: Inverter: 2
12:22:56 I: Unten/ch1/U_DC: 43.200 V
12:22:56 I: Unten/ch1/I_DC: 1.600 A
12:22:56 I: Unten/ch1/P_DC: 68.900 W
12:22:56 I: Unten/ch1/YieldDay: 153.000 Wh
12:22:56 I: Unten/ch1/YieldTotal: 2.762 kWh
12:22:56 I: Unten/ch1/Irradiation: 15.311 %
12:22:56 I: Unten/ch2/U_DC: 41.200 V
12:22:56 I: Unten/ch2/I_DC: 1.810 A
12:22:56 I: Unten/ch2/P_DC: 74.600 W
12:22:56 I: Unten/ch2/YieldDay: 188.000 Wh
12:22:56 I: Unten/ch2/YieldTotal: 3.178 kWh
12:22:56 I: Unten/ch2/Irradiation: 16.578 %
12:22:56 I: Unten/ch0/U_AC: 237.700 V
12:22:56 I: Unten/ch0/I_AC: 0.580 A
12:22:56 I: Unten/ch0/P_AC: 137.100 W
12:22:56 I: Unten/ch0/F_AC: 49.990 Hz
12:22:56 I: Unten/ch0/PF_AC: 1.000 
12:22:56 I: Unten/ch0/Temp: 19.500 °C
12:22:56 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:22:56 I: Unten/ch0/YieldDay: 341.000 Wh
12:22:56 I: Unten/ch0/YieldTotal: 5.940 kWh
12:22:56 I: Unten/ch0/P_DC: 143.500 W
12:22:56 I: Unten/ch0/Efficiency: 95.540 %
12:22:56 I: 
 I: Mitte/ch1/U_DC: 41.400 V
12:22:56 I: Mitte/ch1/I_DC: 1.880 A
12:22:56 I: Mitte/ch1/P_DC: 78.000 W
12:22:56 I: Mitte/ch1/YieldDay: 188.000 Wh
12:22:56 I: Mitte/ch1/YieldTotal: 2.859 kWh
12:22:56 I: Mitte/ch1/Irradiation: 17.333 %
12:22:56 I: Mitte/ch2/U_DC: 41.600 V
12:22:56 I: Mitte/ch2/I_DC: 1.780 A
12:22:56 I: Mitte/ch2/P_DC: 73.900 W
12:22:56 I: Mitte/ch2/YieldDay: 186.000 Wh
12:22:56 I: Mitte/ch2/YieldTotal: 2.459 kWh
12:22:56 I: Mitte/ch2/Irradiation: 16.422 %
12:22:56 I: Mitte/ch0/U_AC: 235.100 V
12:22:56 I: Mitte/ch0/I_AC: 0.620 A
12:22:56 I: Mitte/ch0/P_AC: 145.000 W
12:22:56 I: 12:22:56 I: procPyld: cmd:  11
12:22:56 I: procPyld: txid: 0x95
12:22:56 I: Payload (42): 00 01 01 a4 01 0f 04 72 01 b5 00 e6 03 ed 00 00 0b 2d 00 00 09 9d 00 be 00 bc 09 2b 13 86 07 fe 00 00 00 57 03 e8 00 a8 00 01 
12:22:56 I: procPyld: cmd:  11
12:22:56 I: procPyld: txid: 0x95
12:22:56 I: Payload (42): 00 01 01 a4 01 0f 04 72 01 b5 00 e6 03 ed 00 00 0b 2d 00 00 09 9d 00 be 00 bc 09 2b 13 86 07 fe 00 00 00 57 03 e8 00 a8 00 01 
webSerial, buffer overflow!Inverter: 2
12:23:00 I: Unten/ch1/U_DC: 43.200 V
12:23:00 I: Unten/ch1/I_DC: 1.600 A
12:23:00 I: Unten/ch1/P_DC: 68.900 W
12:23:00 I: Unten/ch1/YieldDay: 153.000 Wh
12:23:00 I: Unten/ch1/YieldTotal: 2.762 kWh
12:23:00 I: Unten/ch1/Irradiation: 15.311 %
12:23:00 I: Unten/ch2/U_DC: 41.200 V
12:23:00 I: Unten/ch2/I_DC: 1.810 A
12:23:00 I: Unten/ch2/P_DC: 74.600 W
12:23:00 I: Unten/ch2/YieldDay: 188.000 Wh
12:23:00 I: Unten/ch2/YieldTotal: 3.178 kWh
12:23:00 I: Unten/ch2/Irradiation: 16.578 %
12:23:00 I: Unten/ch0/U_AC: 237.700 V
12:23:00 I: Unten/ch0/I_AC: 0.580 A
12:23:00 I: Unten/ch0/P_AC: 137.100 W
12:23:00 I: Unten/ch0/F_AC: 49.990 Hz
12:23:00 I: Unten/ch0/PF_AC: 1.000 
12:23:00 I: Unten/ch0/Temp: 19.500 °C
12:23:00 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:00 I: Unten/ch0/YieldDay: 341.000 Wh
12:23:00 I: Unten/ch0/YieldTotal: 5.940 kWh
12:23:00 I: Unten/ch0/P_DC: 143.500 W
12:23:00 I: Unten/ch0/Efficiency: 95.540 %
12:23:00 I: 
nverter: 1
12:23:00 I: Mitte/ch1/U_DC: 42.000 V
12:23:00 I: Mitte/ch1/I_DC: 2.710 A
12:23:00 I: Mitte/ch1/P_DC: 113.800 W
12:23:00 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:00 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:00 I: Mitte/ch1/Irradiation: 25.289 %
12:23:00 I: Mitte/ch2/U_DC: 43.700 V
12:23:00 I: Mitte/ch2/I_DC: 2.300 A
12:23:00 I: Mitte/ch2/P_DC: 100.500 W
12:23:00 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:00 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:00 I: Mitte/ch2/Irradiation: 22.333 %
12:23:00 I: Mitte/ch0/U_AC: 234.700 V
12:23:00 I: Mitte/ch0/I_AC: 0.870 A
12:23:00 I: Mitte/ch0/P_AC: 204.600 W
12:23:00 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:00 I: Mitte/ch0/PF_AC: 1.000 
12:23:00 I: Mitte/ch0/Temp: 16.800 °C
12:23:00 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:00 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:00 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:00 I: Mitte/ch0/P_DC: 214.300 W
12:23:00 I: Mitte/ch0/Efficiency: 95.474 %
12:23:00 I: 
12:23:00 webSerial, buffer overflow!Inverter: 2
12:23:04 I: Unten/ch1/U_DC: 43.200 V
12:23:04 I: Unten/ch1/I_DC: 1.600 A
12:23:04 I: Unten/ch1/P_DC: 68.900 W
12:23:04 I: Unten/ch1/YieldDay: 153.000 Wh
12:23:04 I: Unten/ch1/YieldTotal: 2.762 kWh
12:23:04 I: Unten/ch1/Irradiation: 15.311 %
12:23:04 I: Unten/ch2/U_DC: 41.200 V
12:23:04 I: Unten/ch2/I_DC: 1.810 A
12:23:04 I: Unten/ch2/P_DC: 74.600 W
12:23:04 I: Unten/ch2/YieldDay: 188.000 Wh
12:23:04 I: Unten/ch2/YieldTotal: 3.178 kWh
12:23:04 I: Unten/ch2/Irradiation: 16.578 %
12:23:04 I: Unten/ch0/U_AC: 237.700 V
12:23:04 I: Unten/ch0/I_AC: 0.580 A
12:23:04 I: Unten/ch0/P_AC: 137.100 W
12:23:04 I: Unten/ch0/F_AC: 49.990 Hz
12:23:04 I: Unten/ch0/PF_AC: 1.000 
12:23:04 I: Unten/ch0/Temp: 19.500 °C
12:23:04 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:04 I: Unten/ch0/YieldDay: 341.000 Wh
12:23:04 I: Unten/ch0/YieldTotal: 5.940 kWh
12:23:04 I: Unten/ch0/P_DC: 143.500 W
12:23:04 I: Unten/ch0/Efficiency: 95.540 %
12:23:04 I: 
nverter: 1
12:23:04 I: Mitte/ch1/U_DC: 42.000 V
12:23:04 I: Mitte/ch1/I_DC: 2.710 A
12:23:04 I: Mitte/ch1/P_DC: 113.800 W
12:23:04 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:04 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:04 I: Mitte/ch1/Irradiation: 25.289 %
12:23:04 I: Mitte/ch2/U_DC: 43.700 V
12:23:04 I: Mitte/ch2/I_DC: 2.300 A
12:23:04 I: Mitte/ch2/P_DC: 100.500 W
12:23:04 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:04 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:04 I: Mitte/ch2/Irradiation: 22.333 %
12:23:04 I: Mitte/ch0/U_AC: 234.700 V
12:23:04 I: Mitte/ch0/I_AC: 0.870 A
12:23:04 I: Mitte/ch0/P_AC: 204.600 W
12:23:04 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:04 I: Mitte/ch0/PF_AC: 1.000 
12:23:04 I: Mitte/ch0/Temp: 16.800 °C
12:23:04 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:04 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:04 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:04 I: Mitte/ch0/P_DC: 214.300 W
12:23:04 I: Mitte/ch0/Efficiency: 95.474 %
12:23:04 I: 
12:23:04 webSerial, buffer overflow!Inverter: 2
12:23:08 I: Unten/ch1/U_DC: 43.200 V
12:23:08 I: Unten/ch1/I_DC: 1.600 A
12:23:08 I: Unten/ch1/P_DC: 68.900 W
12:23:08 I: Unten/ch1/YieldDay: 153.000 Wh
12:23:08 I: Unten/ch1/YieldTotal: 2.762 kWh
12:23:08 I: Unten/ch1/Irradiation: 15.311 %
12:23:08 I: Unten/ch2/U_DC: 41.200 V
12:23:08 I: Unten/ch2/I_DC: 1.810 A
12:23:08 I: Unten/ch2/P_DC: 74.600 W
12:23:08 I: Unten/ch2/YieldDay: 188.000 Wh
12:23:08 I: Unten/ch2/YieldTotal: 3.178 kWh
12:23:08 I: Unten/ch2/Irradiation: 16.578 %
12:23:08 I: Unten/ch0/U_AC: 237.700 V
12:23:08 I: Unten/ch0/I_AC: 0.580 A
12:23:08 I: Unten/ch0/P_AC: 137.100 W
12:23:08 I: Unten/ch0/F_AC: 49.990 Hz
12:23:08 I: Unten/ch0/PF_AC: 1.000 
12:23:08 I: Unten/ch0/Temp: 19.500 °C
12:23:08 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:08 I: Unten/ch0/YieldDay: 341.000 Wh
12:23:08 I: Unten/ch0/YieldTotal: 5.940 kWh
12:23:08 I: Unten/ch0/P_DC: 143.500 W
12:23:08 I: Unten/ch0/Efficiency: 95.540 %
12:23:08 I: 
nverter: 1
12:23:08 I: Mitte/ch1/U_DC: 42.000 V
12:23:08 I: Mitte/ch1/I_DC: 2.710 A
12:23:08 I: Mitte/ch1/P_DC: 113.800 W
12:23:08 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:08 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:08 I: Mitte/ch1/Irradiation: 25.289 %
12:23:08 I: Mitte/ch2/U_DC: 43.700 V
12:23:08 I: Mitte/ch2/I_DC: 2.300 A
12:23:08 I: Mitte/ch2/P_DC: 100.500 W
12:23:08 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:08 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:08 I: Mitte/ch2/Irradiation: 22.333 %
12:23:08 I: Mitte/ch0/U_AC: 234.700 V
12:23:08 I: Mitte/ch0/I_AC: 0.870 A
12:23:08 I: Mitte/ch0/P_AC: 204.600 W
12:23:08 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:08 I: Mitte/ch0/PF_AC: 1.000 
12:23:08 I: Mitte/ch0/Temp: 16.800 °C
12:23:08 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:08 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:08 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:08 I: Mitte/ch0/P_DC: 214.300 W
12:23:08 I: Mitte/ch0/Efficiency: 95.474 %
12:23:08 I: 
12:23:08 webSerial, buffer overflow!webSerial, buffer overflow!Inverter: 2
12:23:20 I: Unten/ch1/U_DC: 43.200 V
12:23:20 I: Unten/ch1/I_DC: 1.600 A
12:23:20 I: Unten/ch1/P_DC: 68.900 W
12:23:20 I: Unten/ch1/YieldDay: 153.000 Wh
12:23:20 I: Unten/ch1/YieldTotal: 2.762 kWh
12:23:20 I: Unten/ch1/Irradiation: 15.311 %
12:23:20 I: Unten/ch2/U_DC: 41.200 V
12:23:20 I: Unten/ch2/I_DC: 1.810 A
12:23:20 I: Unten/ch2/P_DC: 74.600 W
12:23:20 I: Unten/ch2/YieldDay: 188.000 Wh
12:23:20 I: Unten/ch2/YieldTotal: 3.178 kWh
12:23:20 I: Unten/ch2/Irradiation: 16.578 %
12:23:20 I: Unten/ch0/U_AC: 237.700 V
12:23:20 I: Unten/ch0/I_AC: 0.580 A
12:23:20 I: Unten/ch0/P_AC: 137.100 W
12:23:20 I: Unten/ch0/F_AC: 49.990 Hz
12:23:20 I: Unten/ch0/PF_AC: 1.000 
12:23:20 I: Unten/ch0/Temp: 19.500 °C
12:23:20 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:20 I: Unten/ch0/YieldDay: 341.000 Wh
12:23:20 I: Unten/ch0/YieldTotal: 5.940 kWh
12:23:20 I: Unten/ch0/P_DC: 143.500 W
12:23:20 I: Unten/ch0/Efficiency: 95.540 %
12:23:20 I: 
nverter: 1
12:23:20 I: Mitte/ch1/U_DC: 42.000 V
12:23:20 I: Mitte/ch1/I_DC: 2.710 A
12:23:20 I: Mitte/ch1/P_DC: 113.800 W
12:23:20 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:20 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:20 I: Mitte/ch1/Irradiation: 25.289 %
12:23:20 I: Mitte/ch2/U_DC: 43.700 V
12:23:20 I: Mitte/ch2/I_DC: 2.300 A
12:23:20 I: Mitte/ch2/P_DC: 100.500 W
12:23:20 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:20 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:20 I: Mitte/ch2/Irradiation: 22.333 %
12:23:20 I: Mitte/ch0/U_AC: 234.700 V
12:23:20 I: Mitte/ch0/I_AC: 0.870 A
12:23:20 I: Mitte/ch0/P_AC: 204.600 W
12:23:20 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:20 I: Mitte/ch0/PF_AC: 1.000 
12:23:20 I: Mitte/ch0/Temp: 16.800 °C
12:23:20 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:20 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:20 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:20 I: Mitte/ch0/P_DC: 214.300 W
12:23:20 I: Mitte/ch0/Efficiency: 95.474 %
12:23:20 I: 
12:23:20 12:23:23 I: resetPayload: id: 2
12:23:23 I: (#2) Requesting Inv SN 114181300000
12:23:23 I: (#2) enqueuedCmd: 11
12:23:23 I: (#2) sendTimePacket
12:23:23 I: TX 27B Ch61 | 15 81 30 32 89 84 10 66 54 80 0b 00 63 a1 9b 2b 00 00 00 01 00 00 00 00 19 83 db 
12:23:23 I: RX 27B Ch3 | 95 81 30 32 89 81 30 32 89 01 00 01 01 b1 00 ae 02 f1 01 9e 00 c3 03 27 00 00 00 
12:23:23 I: RX 27B Ch23 | 95 81 30 32 89 81 30 32 89 01 00 01 01 b1 00 ae 02 f1 01 9e 00 c3 03 27 00 00 00 
12:23:23 I: RX 27B Ch3 | 95 81 30 32 89 81 30 32 89 02 0a cc 00 00 0c 6c 00 9b 00 be 09 4a 13 87 05 d1 17 
12:23:23 I: RX 27B Ch23 | 95 81 30 32 89 81 30 32 89 02 0a cc 00 00 0c 6c 00 9b 00 be 09 4a 13 87 05 d1 17 
webSerial, buffer overflow!Inverter: 2
12:23:24 I: Unten/ch1/U_DC: 43.200 V
12:23:24 I: Unten/ch1/I_DC: 1.600 A
12:23:24 I: Unten/ch1/P_DC: 68.900 W
12:23:24 I: Unten/ch1/YieldDay: 153.000 Wh
12:23:24 I: Unten/ch1/YieldTotal: 2.762 kWh
12:23:24 I: Unten/ch1/Irradiation: 15.311 %
12:23:24 I: Unten/ch2/U_DC: 41.200 V
12:23:24 I: Unten/ch2/I_DC: 1.810 A
12:23:24 I: Unten/ch2/P_DC: 74.600 W
12:23:24 I: Unten/ch2/YieldDay: 188.000 Wh
12:23:24 I: Unten/ch2/YieldTotal: 3.178 kWh
12:23:24 I: Unten/ch2/Irradiation: 16.578 %
12:23:24 I: Unten/ch0/U_AC: 237.700 V
12:23:24 I: Unten/ch0/I_AC: 0.580 A
12:23:24 I: Unten/ch0/P_AC: 137.100 W
12:23:24 I: Unten/ch0/F_AC: 49.990 Hz
12:23:24 I: Unten/ch0/PF_AC: 1.000 
12:23:24 I: Unten/ch0/Temp: 19.500 °C
12:23:24 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:24 I: Unten/ch0/YieldDay: 341.000 Wh
12:23:24 I: Unten/ch0/YieldTotal: 5.940 kWh
12:23:24 I: Unten/ch0/P_DC: 143.500 W
12:23:24 I: Unten/ch0/Efficiency: 95.540 %
12:23:24 I: 
12:23:24 W: while retrieving data: last frame missing: Request Retransmit
12:23:24 I: TX 11B Ch75 | 15 81 30 32 89 84 10 66 54 83 3a 
12:23:24 I: RX 23B Ch3 | 95 81 30 32 89 81 30 32 89 83 00 01 00 3f 03 e8 00 c4 00 01 7c b7 cd 
12:23:24 I: RX 23B Ch23 | 95 81 30 32 89 81 30 32 89 83 00 01 00 3f 03 e8 00 c4 00 01 7c b7 cd 
12:23:24 I: RX 23B Ch23 | 95 81 30 32 89 81 30 32 89 83 00 01 00 3f 03 e8 00 c4 00 01 7c b7 cd 

12:23:24 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:24 I: Mitte/ch2/Irradiation: 22.333 %
12:23:24 I: Mitte/ch0/U_AC: 234.700 V
12:23:24 I: Mitte/ch0/I_AC: 0.870 A
12:23:24 I: Mitte/ch0/P_AC: 204.600 W
12:23:24 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:24 I: Mitte/ch0/PF_AC: 1.000 
12:23:24 I: Mitte/ch0/Temp: 16.800 °C
12:23:24 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:24 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:24 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:24 I: Mitte/ch0/P_DC: 214.300 W
12:23:24 I: Mitte/ch0/Efficiency: 95.474 %
12:23:24 I: 
12:23:24 12:23:25 I: procPyld: cmd:  11
12:23:25 I: procPyld: txid: 0x95
12:23:25 I: Payload (42): 00 01 01 b1 00 ae 02 f1 01 9e 00 c3 03 27 00 00 0a cc 00 00 0c 6c 00 9b 00 be 09 4a 13 87 05 d1 00 01 00 3f 03 e8 00 c4 00 01 
webSerial, buffer overflow!Inverter: 2
12:23:28 I: Unten/ch1/U_DC: 43.300 V
12:23:28 I: Unten/ch1/I_DC: 1.740 A
12:23:28 I: Unten/ch1/P_DC: 75.300 W
12:23:28 I: Unten/ch1/YieldDay: 155.000 Wh
12:23:28 I: Unten/ch1/YieldTotal: 2.764 kWh
12:23:28 I: Unten/ch1/Irradiation: 16.733 %
12:23:28 I: Unten/ch2/U_DC: 41.400 V
12:23:28 I: Unten/ch2/I_DC: 1.950 A
12:23:28 I: Unten/ch2/P_DC: 80.700 W
12:23:28 I: Unten/ch2/YieldDay: 190.000 Wh
12:23:28 I: Unten/ch2/YieldTotal: 3.180 kWh
12:23:28 I: Unten/ch2/Irradiation: 17.933 %
12:23:28 I: Unten/ch0/U_AC: 237.800 V
12:23:28 I: Unten/ch0/I_AC: 0.630 A
12:23:28 I: Unten/ch0/P_AC: 148.900 W
12:23:28 I: Unten/ch0/Q_AC: 0.100 var
12:23:28 I: Unten/ch0/F_AC: 49.990 Hz
12:23:28 I: Unten/ch0/PF_AC: 1.000 
12:23:28 I: Unten/ch0/Temp: 19.600 °C
12:23:28 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:28 I: Unten/ch0/YieldDay: 345.000 Wh
12:23:28 I: Unten/ch0/YieldTotal: 5.944 kWh
12:23:28 I: Unten/ch0/P_DC: 156.000 W
12:23:28 I: Unten/ch0/Efficiency: 95.449 %
12:23:28 I: 
 42.000 V
12:23:28 I: Mitte/ch1/I_DC: 2.710 A
12:23:28 I: Mitte/ch1/P_DC: 113.800 W
12:23:28 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:28 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:28 I: Mitte/ch1/Irradiation: 25.289 %
12:23:28 I: Mitte/ch2/U_DC: 43.700 V
12:23:28 I: Mitte/ch2/I_DC: 2.300 A
12:23:28 I: Mitte/ch2/P_DC: 100.500 W
12:23:28 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:28 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:28 I: Mitte/ch2/Irradiation: 22.333 %
12:23:28 I: Mitte/ch0/U_AC: 234.700 V
12:23:28 I: Mitte/ch0/I_AC: 0.870 A
12:23:28 I: Mitte/ch0/P_AC: 204.600 W
12:23:28 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:28 I: Mitte/ch0/PF_AC: 1.000 
12:23:28 I: Mitte/ch0/Temp: 16.800 °C
12:23:28 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:28 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:28 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:28 I: Mitte/ch0/P_DC: 214.300 W
12:23:28 I: Mitte/ch0/Efficiency: 95.474 %
12:23:28 I: 
12:23:28 webSerial, buffer overflow!Inverter: 2
12:23:32 I: Unten/ch1/U_DC: 43.300 V
12:23:32 I: Unten/ch1/I_DC: 1.740 A
12:23:32 I: Unten/ch1/P_DC: 75.300 W
12:23:32 I: Unten/ch1/YieldDay: 155.000 Wh
12:23:32 I: Unten/ch1/YieldTotal: 2.764 kWh
12:23:32 I: Unten/ch1/Irradiation: 16.733 %
12:23:32 I: Unten/ch2/U_DC: 41.400 V
12:23:32 I: Unten/ch2/I_DC: 1.950 A
12:23:32 I: Unten/ch2/P_DC: 80.700 W
12:23:32 I: Unten/ch2/YieldDay: 190.000 Wh
12:23:32 I: Unten/ch2/YieldTotal: 3.180 kWh
12:23:32 I: Unten/ch2/Irradiation: 17.933 %
12:23:32 I: Unten/ch0/U_AC: 237.800 V
12:23:32 I: Unten/ch0/I_AC: 0.630 A
12:23:32 I: Unten/ch0/P_AC: 148.900 W
12:23:32 I: Unten/ch0/Q_AC: 0.100 var
12:23:32 I: Unten/ch0/F_AC: 49.990 Hz
12:23:32 I: Unten/ch0/PF_AC: 1.000 
12:23:32 I: Unten/ch0/Temp: 19.600 °C
12:23:32 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:32 I: Unten/ch0/YieldDay: 345.000 Wh
12:23:32 I: Unten/ch0/YieldTotal: 5.944 kWh
12:23:32 I: Unten/ch0/P_DC: 156.000 W
12:23:32 I: Unten/ch0/Efficiency: 95.449 %
12:23:32 I: 
 42.000 V
12:23:32 I: Mitte/ch1/I_DC: 2.710 A
12:23:32 I: Mitte/ch1/P_DC: 113.800 W
12:23:32 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:32 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:32 I: Mitte/ch1/Irradiation: 25.289 %
12:23:32 I: Mitte/ch2/U_DC: 43.700 V
12:23:32 I: Mitte/ch2/I_DC: 2.300 A
12:23:32 I: Mitte/ch2/P_DC: 100.500 W
12:23:32 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:32 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:32 I: Mitte/ch2/Irradiation: 22.333 %
12:23:32 I: Mitte/ch0/U_AC: 234.700 V
12:23:32 I: Mitte/ch0/I_AC: 0.870 A
12:23:32 I: Mitte/ch0/P_AC: 204.600 W
12:23:32 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:32 I: Mitte/ch0/PF_AC: 1.000 
12:23:32 I: Mitte/ch0/Temp: 16.800 °C
12:23:32 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:32 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:32 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:32 I: Mitte/ch0/P_DC: 214.300 W
12:23:32 I: Mitte/ch0/Efficiency: 95.474 %
12:23:32 I: 
12:23:32 webSerial, buffer overflow!Inverter: 2
12:23:36 I: Unten/ch1/U_DC: 43.300 V
12:23:36 I: Unten/ch1/I_DC: 1.740 A
12:23:36 I: Unten/ch1/P_DC: 75.300 W
12:23:36 I: Unten/ch1/YieldDay: 155.000 Wh
12:23:36 I: Unten/ch1/YieldTotal: 2.764 kWh
12:23:36 I: Unten/ch1/Irradiation: 16.733 %
12:23:36 I: Unten/ch2/U_DC: 41.400 V
12:23:36 I: Unten/ch2/I_DC: 1.950 A
12:23:36 I: Unten/ch2/P_DC: 80.700 W
12:23:36 I: Unten/ch2/YieldDay: 190.000 Wh
12:23:36 I: Unten/ch2/YieldTotal: 3.180 kWh
12:23:36 I: Unten/ch2/Irradiation: 17.933 %
12:23:36 I: Unten/ch0/U_AC: 237.800 V
12:23:36 I: Unten/ch0/I_AC: 0.630 A
12:23:36 I: Unten/ch0/P_AC: 148.900 W
12:23:36 I: Unten/ch0/Q_AC: 0.100 var
12:23:36 I: Unten/ch0/F_AC: 49.990 Hz
12:23:36 I: Unten/ch0/PF_AC: 1.000 
12:23:36 I: Unten/ch0/Temp: 19.600 °C
12:23:36 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:36 I: Unten/ch0/YieldDay: 345.000 Wh
12:23:36 I: Unten/ch0/YieldTotal: 5.944 kWh
12:23:36 I: Unten/ch0/P_DC: 156.000 W
12:23:36 I: Unten/ch0/Efficiency: 95.449 %
12:23:36 I: 
 42.000 V
12:23:36 I: Mitte/ch1/I_DC: 2.710 A
12:23:36 I: Mitte/ch1/P_DC: 113.800 W
12:23:36 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:36 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:36 I: Mitte/ch1/Irradiation: 25.289 %
12:23:36 I: Mitte/ch2/U_DC: 43.700 V
12:23:36 I: Mitte/ch2/I_DC: 2.300 A
12:23:36 I: Mitte/ch2/P_DC: 100.500 W
12:23:36 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:36 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:36 I: Mitte/ch2/Irradiation: 22.333 %
12:23:36 I: Mitte/ch0/U_AC: 234.700 V
12:23:36 I: Mitte/ch0/I_AC: 0.870 A
12:23:36 I: Mitte/ch0/P_AC: 204.600 W
12:23:36 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:36 I: Mitte/ch0/PF_AC: 1.000 
12:23:36 I: Mitte/ch0/Temp: 16.800 °C
12:23:36 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:36 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:36 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:36 I: Mitte/ch0/P_DC: 214.300 W
12:23:36 I: Mitte/ch0/Efficiency: 95.474 %
12:23:36 I: 
12:23:36 webSerial, buffer overflow!Inverter: 2
12:23:40 I: Unten/ch1/U_DC: 43.300 V
12:23:40 I: Unten/ch1/I_DC: 1.740 A
12:23:40 I: Unten/ch1/P_DC: 75.300 W
12:23:40 I: Unten/ch1/YieldDay: 155.000 Wh
12:23:40 I: Unten/ch1/YieldTotal: 2.764 kWh
12:23:40 I: Unten/ch1/Irradiation: 16.733 %
12:23:40 I: Unten/ch2/U_DC: 41.400 V
12:23:40 I: Unten/ch2/I_DC: 1.950 A
12:23:40 I: Unten/ch2/P_DC: 80.700 W
12:23:40 I: Unten/ch2/YieldDay: 190.000 Wh
12:23:40 I: Unten/ch2/YieldTotal: 3.180 kWh
12:23:40 I: Unten/ch2/Irradiation: 17.933 %
12:23:40 I: Unten/ch0/U_AC: 237.800 V
12:23:40 I: Unten/ch0/I_AC: 0.630 A
12:23:40 I: Unten/ch0/P_AC: 148.900 W
12:23:40 I: Unten/ch0/Q_AC: 0.100 var
12:23:40 I: Unten/ch0/F_AC: 49.990 Hz
12:23:40 I: Unten/ch0/PF_AC: 1.000 
12:23:40 I: Unten/ch0/Temp: 19.600 °C
12:23:40 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:40 I: Unten/ch0/YieldDay: 345.000 Wh
12:23:40 I: Unten/ch0/YieldTotal: 5.944 kWh
12:23:40 I: Unten/ch0/P_DC: 156.000 W
12:23:40 I: Unten/ch0/Efficiency: 95.449 %
12:23:40 I: 
 42.000 V
12:23:40 I: Mitte/ch1/I_DC: 2.710 A
12:23:40 I: Mitte/ch1/P_DC: 113.800 W
12:23:40 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:40 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:40 I: Mitte/ch1/Irradiation: 25.289 %
12:23:40 I: Mitte/ch2/U_DC: 43.700 V
12:23:40 I: Mitte/ch2/I_DC: 2.300 A
12:23:40 I: Mitte/ch2/P_DC: 100.500 W
12:23:40 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:40 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:40 I: Mitte/ch2/Irradiation: 22.333 %
12:23:40 I: Mitte/ch0/U_AC: 234.700 V
12:23:40 I: Mitte/ch0/I_AC: 0.870 A
12:23:40 I: Mitte/ch0/P_AC: 204.600 W
12:23:40 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:40 I: Mitte/ch0/PF_AC: 1.000 
12:23:40 I: Mitte/ch0/Temp: 16.800 °C
12:23:40 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:40 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:40 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:40 I: Mitte/ch0/P_DC: 214.300 W
12:23:40 I: Mitte/ch0/Efficiency: 95.474 %
12:23:40 I: 
12:23:40 webSerial, buffer overflow!Inverter: 2
12:23:44 I: Unten/ch1/U_DC: 43.300 V
12:23:44 I: Unten/ch1/I_DC: 1.740 A
12:23:44 I: Unten/ch1/P_DC: 75.300 W
12:23:44 I: Unten/ch1/YieldDay: 155.000 Wh
12:23:44 I: Unten/ch1/YieldTotal: 2.764 kWh
12:23:44 I: Unten/ch1/Irradiation: 16.733 %
12:23:44 I: Unten/ch2/U_DC: 41.400 V
12:23:44 I: Unten/ch2/I_DC: 1.950 A
12:23:44 I: Unten/ch2/P_DC: 80.700 W
12:23:44 I: Unten/ch2/YieldDay: 190.000 Wh
12:23:44 I: Unten/ch2/YieldTotal: 3.180 kWh
12:23:44 I: Unten/ch2/Irradiation: 17.933 %
12:23:44 I: Unten/ch0/U_AC: 237.800 V
12:23:44 I: Unten/ch0/I_AC: 0.630 A
12:23:44 I: Unten/ch0/P_AC: 148.900 W
12:23:44 I: Unten/ch0/Q_AC: 0.100 var
12:23:44 I: Unten/ch0/F_AC: 49.990 Hz
12:23:44 I: Unten/ch0/PF_AC: 1.000 
12:23:44 I: Unten/ch0/Temp: 19.600 °C
12:23:44 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:44 I: Unten/ch0/YieldDay: 345.000 Wh
12:23:44 I: Unten/ch0/YieldTotal: 5.944 kWh
12:23:44 I: Unten/ch0/P_DC: 156.000 W
12:23:44 I: Unten/ch0/Efficiency: 95.449 %
12:23:44 I: 
 42.000 V
12:23:44 I: Mitte/ch1/I_DC: 2.710 A
12:23:44 I: Mitte/ch1/P_DC: 113.800 W
12:23:44 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:44 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:44 I: Mitte/ch1/Irradiation: 25.289 %
12:23:44 I: Mitte/ch2/U_DC: 43.700 V
12:23:44 I: Mitte/ch2/I_DC: 2.300 A
12:23:44 I: Mitte/ch2/P_DC: 100.500 W
12:23:44 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:44 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:44 I: Mitte/ch2/Irradiation: 22.333 %
12:23:44 I: Mitte/ch0/U_AC: 234.700 V
12:23:44 I: Mitte/ch0/I_AC: 0.870 A
12:23:44 I: Mitte/ch0/P_AC: 204.600 W
12:23:44 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:44 I: Mitte/ch0/PF_AC: 1.000 
12:23:44 I: Mitte/ch0/Temp: 16.800 °C
12:23:44 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:44 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:44 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:44 I: Mitte/ch0/P_DC: 214.300 W
12:23:44 I: Mitte/ch0/Efficiency: 95.474 %
12:23:44 I: 
12:23:44 webSerial, buffer overflow!Inverter: 2
12:23:48 I: Unten/ch1/U_DC: 43.300 V
12:23:48 I: Unten/ch1/I_DC: 1.740 A
12:23:48 I: Unten/ch1/P_DC: 75.300 W
12:23:48 I: Unten/ch1/YieldDay: 155.000 Wh
12:23:48 I: Unten/ch1/YieldTotal: 2.764 kWh
12:23:48 I: Unten/ch1/Irradiation: 16.733 %
12:23:48 I: Unten/ch2/U_DC: 41.400 V
12:23:48 I: Unten/ch2/I_DC: 1.950 A
12:23:48 I: Unten/ch2/P_DC: 80.700 W
12:23:48 I: Unten/ch2/YieldDay: 190.000 Wh
12:23:48 I: Unten/ch2/YieldTotal: 3.180 kWh
12:23:48 I: Unten/ch2/Irradiation: 17.933 %
12:23:48 I: Unten/ch0/U_AC: 237.800 V
12:23:48 I: Unten/ch0/I_AC: 0.630 A
12:23:48 I: Unten/ch0/P_AC: 148.900 W
12:23:48 I: Unten/ch0/Q_AC: 0.100 var
12:23:48 I: Unten/ch0/F_AC: 49.990 Hz
12:23:48 I: Unten/ch0/PF_AC: 1.000 
12:23:48 I: Unten/ch0/Temp: 19.600 °C
12:23:48 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:48 I: Unten/ch0/YieldDay: 345.000 Wh
12:23:48 I: Unten/ch0/YieldTotal: 5.944 kWh
12:23:48 I: Unten/ch0/P_DC: 156.000 W
12:23:48 I: Unten/ch0/Efficiency: 95.449 %
12:23:48 I: 
 42.000 V
12:23:48 I: Mitte/ch1/I_DC: 2.710 A
12:23:48 I: Mitte/ch1/P_DC: 113.800 W
12:23:48 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:48 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:48 I: Mitte/ch1/Irradiation: 25.289 %
12:23:48 I: Mitte/ch2/U_DC: 43.700 V
12:23:48 I: Mitte/ch2/I_DC: 2.300 A
12:23:48 I: Mitte/ch2/P_DC: 100.500 W
12:23:48 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:48 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:48 I: Mitte/ch2/Irradiation: 22.333 %
12:23:48 I: Mitte/ch0/U_AC: 234.700 V
12:23:48 I: Mitte/ch0/I_AC: 0.870 A
12:23:48 I: Mitte/ch0/P_AC: 204.600 W
12:23:48 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:48 I: Mitte/ch0/PF_AC: 1.000 
12:23:48 I: Mitte/ch0/Temp: 16.800 °C
12:23:48 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:48 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:48 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:48 I: Mitte/ch0/P_DC: 214.300 W
12:23:48 I: Mitte/ch0/Efficiency: 95.474 %
12:23:48 I: 
12:23:48 webSerial, buffer overflow!
12:23:52 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:52 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:52 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:52 I: Mitte/ch0/P_DC: 214.300 W
12:23:52 I: Mitte/ch0/Efficiency: 95.474 %
12:23:52 I: 
12:23:52 I: Inverter: 2
12:23:52 I: Unten/ch1/U_DC: 43.300 V
12:23:52 I: Unten/ch1/I_DC: 1.740 A
12:23:52 I: Unten/ch1/P_DC: 75.300 W
12:23:52 I: Unten/ch1/YieldDay: 155.000 Wh
12:23:52 I: Unten/ch1/YieldTotal: 2.764 kWh
12:23:52 I: Unten/ch1/Irradiation: 16.733 %
12:23:52 I: Unten/ch2/U_DC: 41.400 V
12:23:52 I: Unten/ch2/I_DC: 1.950 A
12:23:52 I: Unten/ch2/P_DC: 80.700 W
12:23:52 I: Unten/ch2/YieldDay: 190.000 Wh
12:23:52 I: Unten/ch2/YieldTotal: 3.180 kWh
12:23:52 I: Unten/ch2/Irradiation: 17.933 %
12:23:52 I: Unten/ch0/U_AC: 237.800 V
12:23:52 I: Unten/ch0/I_AC: 0.630 A
12:23:52 I: Unten/ch0/P_AC: 148.900 W
12:23:52 I: Unten/ch0/Q_AC: 0.100 var
12:23:52 I: Unten/ch0/F_AC: 49.990 Hz
12:23:52 I: Unten/ch0/PF_AC: 1.000 
12:23:52 I: Unten/ch0/Temp: 19.600 °C
12:23:52 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:52 I: Unten/ch0/YieldDay: 345.000 Wh
12:23:52 I: Unten/ch0/YieldTotal: 5.944 kWh
12:23:52 I: Unten/ch0/P_DC: 156.000 W
12:23:52 I: Unten/ch0/Efficiency: 95.449 %
12:23:52 I: 
12:23:52 I: RX 27B Ch3 | 95 81 30 29 73 81 30 29 73 01 00 01 01 a4 00 77 01 f5 01 a1 00 73 01 e1 00 00 80 
12:23:52 I: RX 27B Ch3 | 95 81 30 29 73 81 30 29 73 01 00 01 01 a4 00 77 01 f5 01 a1 00 73 01 e1 00 00 80 
12:23:52 I: RX 27B Ch3 | 95 81 30 29 73 81 30 29 73 01 00 01 01 a4 00 77 01 f5 01 a1 00 73 01 e1 00 00 80 
I: Mitte/ch2/P_DC: 100.500 W
12:23:52 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:52 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:52 I: Mitte/ch2/Irradiation: 22.333 %
12:23:52 I: Mitte/ch0/U_AC: 234.700 V
12:23:52 I: Mitte/ch0/I_AC: 0.870 A
12:23:52 I: Mitte/ch0/P_AC: 204.600 W
12:23:52 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:52 I: Mitte/ch0/PF_AC: 1.000 
12:23:52 I: 12:23:53 W: while retrieving data: last frame missing: Request Retransmit
12:23:53 I: TX 11B Ch23 | 15 81 30 29 73 84 10 66 54 83 db 
12:23:53 I: RX 23B Ch3 | 95 81 30 29 73 81 30 29 73 83 00 01 00 27 03 e8 00 90 00 01 f5 ad 12 
12:23:53 I: RX 23B Ch3 | 95 81 30 29 73 81 30 29 73 83 00 01 00 27 03 e8 00 90 00 01 f5 ad 12 
12:23:53 I: RX 23B Ch23 | 95 81 30 29 73 81 30 29 73 83 00 01 00 27 03 e8 00 90 00 01 f5 ad 12 
12:23:54 W: while retrieving data: Frame 2 missing: Request Retransmit
12:23:54 I: TX 11B Ch40 | 15 81 30 29 73 84 10 66 54 82 da 
12:23:54 W: while retrieving data: Frame 2 missing: Request Retransmit
12:23:54 I: TX 11B Ch61 | 15 81 30 29 73 84 10 66 54 82 da 
12:23:54 I: RX 27B Ch3 | 95 81 30 29 73 81 30 29 73 02 08 b9 00 00 08 ce 00 a7 00 83 09 4d 13 87 03 aa bd 
12:23:54 I: RX 27B Ch23 | 95 81 30 29 73 81 30 29 73 02 08 b9 00 00 08 ce 00 a7 00 83 09 4d 13 87 03 aa bd 
12:23:54 I: RX 27B Ch23 | 95 81 30 29 73 81 30 29 73 02 08 b9 00 00 08 ce 00 a7 00 83 09 4d 13 87 03 aa bd 
12:23:55 I: procPyld: cmd:  11
12:23:55 I: procPyld: txid: 0x95
12:23:55 I: Payload (42): 00 01 01 a4 00 77 01 f5 01 a1 00 73 01 e1 00 00 08 b9 00 00 08 ce 00 a7 00 83 09 4d 13 87 03 aa 00 01 00 27 03 e8 00 90 00 01 
webSerial, buffer overflow!
12:23:56 I: 
12:23:56 I: Inverter: 2
12:23:56 I: Unten/ch1/U_DC: 43.300 V
12:23:56 I: Unten/ch1/I_DC: 1.740 A
12:23:56 I: Unten/ch1/P_DC: 75.300 W
12:23:56 I: Unten/ch1/YieldDay: 155.000 Wh
12:23:56 I: Unten/ch1/YieldTotal: 2.764 kWh
12:23:56 I: Unten/ch1/Irradiation: 16.733 %
12:23:56 I: Unten/ch2/U_DC: 41.400 V
12:23:56 I: Unten/ch2/I_DC: 1.950 A
12:23:56 I: Unten/ch2/P_DC: 80.700 W
12:23:56 I: Unten/ch2/YieldDay: 190.000 Wh
12:23:56 I: Unten/ch2/YieldTotal: 3.180 kWh
12:23:56 I: Unten/ch2/Irradiation: 17.933 %
12:23:56 I: Unten/ch0/U_AC: 237.800 V
12:23:56 I: Unten/ch0/I_AC: 0.630 A
12:23:56 I: Unten/ch0/P_AC: 148.900 W
12:23:56 I: Unten/ch0/Q_AC: 0.100 var
12:23:56 I: Unten/ch0/F_AC: 49.990 Hz
12:23:56 I: Unten/ch0/PF_AC: 1.000 
12:23:56 I: Unten/ch0/Temp: 19.600 °C
12:23:56 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:23:56 I: Unten/ch0/YieldDay: 345.000 Wh
12:23:56 I: Unten/ch0/YieldTotal: 5.944 kWh
12:23:56 I: Unten/ch0/P_DC: 156.000 W
12:23:56 I: Unten/ch0/Efficiency: 95.449 %
12:23:56 I: 
h1/U_DC: 42.000 V
12:23:56 I: Mitte/ch1/I_DC: 2.710 A
12:23:56 I: Mitte/ch1/P_DC: 113.800 W
12:23:56 I: Mitte/ch1/YieldDay: 190.000 Wh
12:23:56 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:23:56 I: Mitte/ch1/Irradiation: 25.289 %
12:23:56 I: Mitte/ch2/U_DC: 43.700 V
12:23:56 I: Mitte/ch2/I_DC: 2.300 A
12:23:56 I: Mitte/ch2/P_DC: 100.500 W
12:23:56 I: Mitte/ch2/YieldDay: 188.000 Wh
12:23:56 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:23:56 I: Mitte/ch2/Irradiation: 22.333 %
12:23:56 I: Mitte/ch0/U_AC: 234.700 V
12:23:56 I: Mitte/ch0/I_AC: 0.870 A
12:23:56 I: Mitte/ch0/P_AC: 204.600 W
12:23:56 I: Mitte/ch0/F_AC: 49.980 Hz
12:23:56 I: Mitte/ch0/PF_AC: 1.000 
12:23:56 I: Mitte/ch0/Temp: 16.800 °C
12:23:56 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:23:56 I: Mitte/ch0/YieldDay: 378.000 Wh
12:23:56 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:23:56 I: Mitte/ch0/P_DC: 214.300 W
12:23:56 I: webSerial, buffer overflow!
12:24:00 I: 
12:24:00 I: Inverter: 2
12:24:00 I: Unten/ch1/U_DC: 43.300 V
12:24:00 I: Unten/ch1/I_DC: 1.740 A
12:24:00 I: Unten/ch1/P_DC: 75.300 W
12:24:00 I: Unten/ch1/YieldDay: 155.000 Wh
12:24:00 I: Unten/ch1/YieldTotal: 2.764 kWh
12:24:00 I: Unten/ch1/Irradiation: 16.733 %
12:24:00 I: Unten/ch2/U_DC: 41.400 V
12:24:00 I: Unten/ch2/I_DC: 1.950 A
12:24:00 I: Unten/ch2/P_DC: 80.700 W
12:24:00 I: Unten/ch2/YieldDay: 190.000 Wh
12:24:00 I: Unten/ch2/YieldTotal: 3.180 kWh
12:24:00 I: Unten/ch2/Irradiation: 17.933 %
12:24:00 I: Unten/ch0/U_AC: 237.800 V
12:24:00 I: Unten/ch0/I_AC: 0.630 A
12:24:00 I: Unten/ch0/P_AC: 148.900 W
12:24:00 I: Unten/ch0/Q_AC: 0.100 var
12:24:00 I: Unten/ch0/F_AC: 49.990 Hz
12:24:00 I: Unten/ch0/PF_AC: 1.000 
12:24:00 I: Unten/ch0/Temp: 19.600 °C
12:24:00 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:24:00 I: Unten/ch0/YieldDay: 345.000 Wh
12:24:00 I: Unten/ch0/YieldTotal: 5.944 kWh
12:24:00 I: Unten/ch0/P_DC: 156.000 W
12:24:00 I: Unten/ch0/Efficiency: 95.449 %
12:24:00 I: 
h1/U_DC: 42.000 V
12:24:00 I: Mitte/ch1/I_DC: 2.710 A
12:24:00 I: Mitte/ch1/P_DC: 113.800 W
12:24:00 I: Mitte/ch1/YieldDay: 190.000 Wh
12:24:00 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:24:00 I: Mitte/ch1/Irradiation: 25.289 %
12:24:00 I: Mitte/ch2/U_DC: 43.700 V
12:24:00 I: Mitte/ch2/I_DC: 2.300 A
12:24:00 I: Mitte/ch2/P_DC: 100.500 W
12:24:00 I: Mitte/ch2/YieldDay: 188.000 Wh
12:24:00 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:24:00 I: Mitte/ch2/Irradiation: 22.333 %
12:24:00 I: Mitte/ch0/U_AC: 234.700 V
12:24:00 I: Mitte/ch0/I_AC: 0.870 A
12:24:00 I: Mitte/ch0/P_AC: 204.600 W
12:24:00 I: Mitte/ch0/F_AC: 49.980 Hz
12:24:00 I: Mitte/ch0/PF_AC: 1.000 
12:24:00 I: Mitte/ch0/Temp: 16.800 °C
12:24:00 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:24:00 I: Mitte/ch0/YieldDay: 378.000 Wh
12:24:00 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:24:00 I: Mitte/ch0/P_DC: 214.300 W
12:24:00 I: webSerial, buffer overflow!
12:24:04 I: 
12:24:04 I: Inverter: 2
12:24:04 I: Unten/ch1/U_DC: 43.300 V
12:24:04 I: Unten/ch1/I_DC: 1.740 A
12:24:04 I: Unten/ch1/P_DC: 75.300 W
12:24:04 I: Unten/ch1/YieldDay: 155.000 Wh
12:24:04 I: Unten/ch1/YieldTotal: 2.764 kWh
12:24:04 I: Unten/ch1/Irradiation: 16.733 %
12:24:04 I: Unten/ch2/U_DC: 41.400 V
12:24:04 I: Unten/ch2/I_DC: 1.950 A
12:24:04 I: Unten/ch2/P_DC: 80.700 W
12:24:04 I: Unten/ch2/YieldDay: 190.000 Wh
12:24:04 I: Unten/ch2/YieldTotal: 3.180 kWh
12:24:04 I: Unten/ch2/Irradiation: 17.933 %
12:24:04 I: Unten/ch0/U_AC: 237.800 V
12:24:04 I: Unten/ch0/I_AC: 0.630 A
12:24:04 I: Unten/ch0/P_AC: 148.900 W
12:24:04 I: Unten/ch0/Q_AC: 0.100 var
12:24:04 I: Unten/ch0/F_AC: 49.990 Hz
12:24:04 I: Unten/ch0/PF_AC: 1.000 
12:24:04 I: Unten/ch0/Temp: 19.600 °C
12:24:04 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:24:04 I: Unten/ch0/YieldDay: 345.000 Wh
12:24:04 I: Unten/ch0/YieldTotal: 5.944 kWh
12:24:04 I: Unten/ch0/P_DC: 156.000 W
12:24:04 I: Unten/ch0/Efficiency: 95.449 %
12:24:04 I: 
h1/U_DC: 42.000 V
12:24:04 I: Mitte/ch1/I_DC: 2.710 A
12:24:04 I: Mitte/ch1/P_DC: 113.800 W
12:24:04 I: Mitte/ch1/YieldDay: 190.000 Wh
12:24:04 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:24:04 I: Mitte/ch1/Irradiation: 25.289 %
12:24:04 I: Mitte/ch2/U_DC: 43.700 V
12:24:04 I: Mitte/ch2/I_DC: 2.300 A
12:24:04 I: Mitte/ch2/P_DC: 100.500 W
12:24:04 I: Mitte/ch2/YieldDay: 188.000 Wh
12:24:04 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:24:04 I: Mitte/ch2/Irradiation: 22.333 %
12:24:04 I: Mitte/ch0/U_AC: 234.700 V
12:24:04 I: Mitte/ch0/I_AC: 0.870 A
12:24:04 I: Mitte/ch0/P_AC: 204.600 W
12:24:04 I: Mitte/ch0/F_AC: 49.980 Hz
12:24:04 I: Mitte/ch0/PF_AC: 1.000 
12:24:04 I: Mitte/ch0/Temp: 16.800 °C
12:24:04 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:24:04 I: Mitte/ch0/YieldDay: 378.000 Wh
12:24:04 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:24:04 I: Mitte/ch0/P_DC: 214.300 W
12:24:04 I: webSerial, buffer overflow!
12:24:08 I: 
12:24:08 I: Inverter: 2
12:24:08 I: Unten/ch1/U_DC: 43.300 V
12:24:08 I: Unten/ch1/I_DC: 1.740 A
12:24:08 I: Unten/ch1/P_DC: 75.300 W
12:24:08 I: Unten/ch1/YieldDay: 155.000 Wh
12:24:08 I: Unten/ch1/YieldTotal: 2.764 kWh
12:24:08 I: Unten/ch1/Irradiation: 16.733 %
12:24:08 I: Unten/ch2/U_DC: 41.400 V
12:24:08 I: Unten/ch2/I_DC: 1.950 A
12:24:08 I: Unten/ch2/P_DC: 80.700 W
12:24:08 I: Unten/ch2/YieldDay: 190.000 Wh
12:24:08 I: Unten/ch2/YieldTotal: 3.180 kWh
12:24:08 I: Unten/ch2/Irradiation: 17.933 %
12:24:08 I: Unten/ch0/U_AC: 237.800 V
12:24:08 I: Unten/ch0/I_AC: 0.630 A
12:24:08 I: Unten/ch0/P_AC: 148.900 W
12:24:08 I: Unten/ch0/Q_AC: 0.100 var
12:24:08 I: Unten/ch0/F_AC: 49.990 Hz
12:24:08 I: Unten/ch0/PF_AC: 1.000 
12:24:08 I: Unten/ch0/Temp: 19.600 °C
12:24:08 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:24:08 I: Unten/ch0/YieldDay: 345.000 Wh
12:24:08 I: Unten/ch0/YieldTotal: 5.944 kWh
12:24:08 I: Unten/ch0/P_DC: 156.000 W
12:24:08 I: Unten/ch0/Efficiency: 95.449 %
12:24:08 I: 
h1/U_DC: 42.000 V
12:24:08 I: Mitte/ch1/I_DC: 2.710 A
12:24:08 I: Mitte/ch1/P_DC: 113.800 W
12:24:08 I: Mitte/ch1/YieldDay: 190.000 Wh
12:24:08 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:24:08 I: Mitte/ch1/Irradiation: 25.289 %
12:24:08 I: Mitte/ch2/U_DC: 43.700 V
12:24:08 I: Mitte/ch2/I_DC: 2.300 A
12:24:08 I: Mitte/ch2/P_DC: 100.500 W
12:24:08 I: Mitte/ch2/YieldDay: 188.000 Wh
12:24:08 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:24:08 I: Mitte/ch2/Irradiation: 22.333 %
12:24:08 I: Mitte/ch0/U_AC: 234.700 V
12:24:08 I: Mitte/ch0/I_AC: 0.870 A
12:24:08 I: Mitte/ch0/P_AC: 204.600 W
12:24:08 I: Mitte/ch0/F_AC: 49.980 Hz
12:24:08 I: Mitte/ch0/PF_AC: 1.000 
12:24:08 I: Mitte/ch0/Temp: 16.800 °C
12:24:08 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:24:08 I: Mitte/ch0/YieldDay: 378.000 Wh
12:24:08 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:24:08 I: Mitte/ch0/P_DC: 214.300 W
12:24:08 I: webSerial, buffer overflow!
12:24:12 I: 
12:24:12 I: Inverter: 2
12:24:12 I: Unten/ch1/U_DC: 43.300 V
12:24:12 I: Unten/ch1/I_DC: 1.740 A
12:24:12 I: Unten/ch1/P_DC: 75.300 W
12:24:12 I: Unten/ch1/YieldDay: 155.000 Wh
12:24:12 I: Unten/ch1/YieldTotal: 2.764 kWh
12:24:12 I: Unten/ch1/Irradiation: 16.733 %
12:24:12 I: Unten/ch2/U_DC: 41.400 V
12:24:12 I: Unten/ch2/I_DC: 1.950 A
12:24:12 I: Unten/ch2/P_DC: 80.700 W
12:24:12 I: Unten/ch2/YieldDay: 190.000 Wh
12:24:12 I: Unten/ch2/YieldTotal: 3.180 kWh
12:24:12 I: Unten/ch2/Irradiation: 17.933 %
12:24:12 I: Unten/ch0/U_AC: 237.800 V
12:24:12 I: Unten/ch0/I_AC: 0.630 A
12:24:12 I: Unten/ch0/P_AC: 148.900 W
12:24:12 I: Unten/ch0/Q_AC: 0.100 var
12:24:12 I: Unten/ch0/F_AC: 49.990 Hz
12:24:12 I: Unten/ch0/PF_AC: 1.000 
12:24:12 I: Unten/ch0/Temp: 19.600 °C
12:24:12 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:24:12 I: Unten/ch0/YieldDay: 345.000 Wh
12:24:12 I: Unten/ch0/YieldTotal: 5.944 kWh
12:24:12 I: Unten/ch0/P_DC: 156.000 W
12:24:12 I: Unten/ch0/Efficiency: 95.449 %
12:24:12 I: 
h1/U_DC: 42.000 V
12:24:12 I: Mitte/ch1/I_DC: 2.710 A
12:24:12 I: Mitte/ch1/P_DC: 113.800 W
12:24:12 I: Mitte/ch1/YieldDay: 190.000 Wh
12:24:12 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:24:12 I: Mitte/ch1/Irradiation: 25.289 %
12:24:12 I: Mitte/ch2/U_DC: 43.700 V
12:24:12 I: Mitte/ch2/I_DC: 2.300 A
12:24:12 I: Mitte/ch2/P_DC: 100.500 W
12:24:12 I: Mitte/ch2/YieldDay: 188.000 Wh
12:24:12 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:24:12 I: Mitte/ch2/Irradiation: 22.333 %
12:24:12 I: Mitte/ch0/U_AC: 234.700 V
12:24:12 I: Mitte/ch0/I_AC: 0.870 A
12:24:12 I: Mitte/ch0/P_AC: 204.600 W
12:24:12 I: Mitte/ch0/F_AC: 49.980 Hz
12:24:12 I: Mitte/ch0/PF_AC: 1.000 
12:24:12 I: Mitte/ch0/Temp: 16.800 °C
12:24:12 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:24:12 I: Mitte/ch0/YieldDay: 378.000 Wh
12:24:12 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:24:12 I: Mitte/ch0/P_DC: 214.300 W
12:24:12 I: webSerial, buffer overflow!
12:24:16 I: 
12:24:16 I: Inverter: 2
12:24:16 I: Unten/ch1/U_DC: 43.300 V
12:24:16 I: Unten/ch1/I_DC: 1.740 A
12:24:16 I: Unten/ch1/P_DC: 75.300 W
12:24:16 I: Unten/ch1/YieldDay: 155.000 Wh
12:24:16 I: Unten/ch1/YieldTotal: 2.764 kWh
12:24:16 I: Unten/ch1/Irradiation: 16.733 %
12:24:16 I: Unten/ch2/U_DC: 41.400 V
12:24:16 I: Unten/ch2/I_DC: 1.950 A
12:24:16 I: Unten/ch2/P_DC: 80.700 W
12:24:16 I: Unten/ch2/YieldDay: 190.000 Wh
12:24:16 I: Unten/ch2/YieldTotal: 3.180 kWh
12:24:16 I: Unten/ch2/Irradiation: 17.933 %
12:24:16 I: Unten/ch0/U_AC: 237.800 V
12:24:16 I: Unten/ch0/I_AC: 0.630 A
12:24:16 I: Unten/ch0/P_AC: 148.900 W
12:24:16 I: Unten/ch0/Q_AC: 0.100 var
12:24:16 I: Unten/ch0/F_AC: 49.990 Hz
12:24:16 I: Unten/ch0/PF_AC: 1.000 
12:24:16 I: Unten/ch0/Temp: 19.600 °C
12:24:16 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:24:16 I: Unten/ch0/YieldDay: 345.000 Wh
12:24:16 I: Unten/ch0/YieldTotal: 5.944 kWh
12:24:16 I: Unten/ch0/P_DC: 156.000 W
12:24:16 I: Unten/ch0/Efficiency: 95.449 %
12:24:16 I: 
h1/U_DC: 42.000 V
12:24:16 I: Mitte/ch1/I_DC: 2.710 A
12:24:16 I: Mitte/ch1/P_DC: 113.800 W
12:24:16 I: Mitte/ch1/YieldDay: 190.000 Wh
12:24:16 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:24:16 I: Mitte/ch1/Irradiation: 25.289 %
12:24:16 I: Mitte/ch2/U_DC: 43.700 V
12:24:16 I: Mitte/ch2/I_DC: 2.300 A
12:24:16 I: Mitte/ch2/P_DC: 100.500 W
12:24:16 I: Mitte/ch2/YieldDay: 188.000 Wh
12:24:16 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:24:16 I: Mitte/ch2/Irradiation: 22.333 %
12:24:16 I: Mitte/ch0/U_AC: 234.700 V
12:24:16 I: Mitte/ch0/I_AC: 0.870 A
12:24:16 I: Mitte/ch0/P_AC: 204.600 W
12:24:16 I: Mitte/ch0/F_AC: 49.980 Hz
12:24:16 I: Mitte/ch0/PF_AC: 1.000 
12:24:16 I: Mitte/ch0/Temp: 16.800 °C
12:24:16 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:24:16 I: Mitte/ch0/YieldDay: 378.000 Wh
12:24:16 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:24:16 I: Mitte/ch0/P_DC: 214.300 W
12:24:16 I: webSerial, buffer overflow!
12:24:20 I: 
12:24:20 I: Inverter: 2
12:24:20 I: Unten/ch1/U_DC: 43.300 V
12:24:20 I: Unten/ch1/I_DC: 1.740 A
12:24:20 I: Unten/ch1/P_DC: 75.300 W
12:24:20 I: Unten/ch1/YieldDay: 155.000 Wh
12:24:20 I: Unten/ch1/YieldTotal: 2.764 kWh
12:24:20 I: Unten/ch1/Irradiation: 16.733 %
12:24:20 I: Unten/ch2/U_DC: 41.400 V
12:24:20 I: Unten/ch2/I_DC: 1.950 A
12:24:20 I: Unten/ch2/P_DC: 80.700 W
12:24:20 I: Unten/ch2/YieldDay: 190.000 Wh
12:24:20 I: Unten/ch2/YieldTotal: 3.180 kWh
12:24:20 I: Unten/ch2/Irradiation: 17.933 %
12:24:20 I: Unten/ch0/U_AC: 237.800 V
12:24:20 I: Unten/ch0/I_AC: 0.630 A
12:24:20 I: Unten/ch0/P_AC: 148.900 W
12:24:20 I: Unten/ch0/Q_AC: 0.100 var
12:24:20 I: Unten/ch0/F_AC: 49.990 Hz
12:24:20 I: Unten/ch0/PF_AC: 1.000 
12:24:20 I: Unten/ch0/Temp: 19.600 °C
12:24:20 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:24:20 I: Unten/ch0/YieldDay: 345.000 Wh
12:24:20 I: Unten/ch0/YieldTotal: 5.944 kWh
12:24:20 I: Unten/ch0/P_DC: 156.000 W
12:24:20 I: Unten/ch0/Efficiency: 95.449 %
12:24:20 I: 
h1/U_DC: 42.000 V
12:24:20 I: Mitte/ch1/I_DC: 2.710 A
12:24:20 I: Mitte/ch1/P_DC: 113.800 W
12:24:20 I: Mitte/ch1/YieldDay: 190.000 Wh
12:24:20 I: Mitte/ch1/YieldTotal: 2.861 kWh
12:24:20 I: Mitte/ch1/Irradiation: 25.289 %
12:24:20 I: Mitte/ch2/U_DC: 43.700 V
12:24:20 I: Mitte/ch2/I_DC: 2.300 A
12:24:20 I: Mitte/ch2/P_DC: 100.500 W
12:24:20 I: Mitte/ch2/YieldDay: 188.000 Wh
12:24:20 I: Mitte/ch2/YieldTotal: 2.461 kWh
12:24:20 I: Mitte/ch2/Irradiation: 22.333 %
12:24:20 I: Mitte/ch0/U_AC: 234.700 V
12:24:20 I: Mitte/ch0/I_AC: 0.870 A
12:24:20 I: Mitte/ch0/P_AC: 204.600 W
12:24:20 I: Mitte/ch0/F_AC: 49.980 Hz
12:24:20 I: Mitte/ch0/PF_AC: 1.000 
12:24:20 I: Mitte/ch0/Temp: 16.800 °C
12:24:20 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:24:20 I: Mitte/ch0/YieldDay: 378.000 Wh
12:24:20 I: Mitte/ch0/YieldTotal: 5.322 kWh
12:24:20 I: Mitte/ch0/P_DC: 214.300 W
12:24:20 I: 12:24:21 I: resetPayload: id: 1
12:24:21 I: (#1) Requesting Inv SN 114181300000
12:24:21 I: (#1) enqueuedCmd: 11
12:24:21 I: (#1) sendTimePacket
12:24:21 I: TX 27B Ch75 | 15 81 30 49 61 84 10 66 54 80 0b 00 63 a1 9b 65 00 00 00 01 00 00 00 00 ba fe d8 
12:24:21 I: RX 27B Ch3 | 95 81 30 49 61 81 30 49 61 01 00 01 01 a6 01 16 04 95 01 c4 00 b6 03 35 00 00 f1 
12:24:21 I: RX 27B Ch23 | 95 81 30 49 61 81 30 49 61 01 00 01 01 a6 01 16 04 95 01 c4 00 b6 03 35 00 00 f1 
12:24:21 I: RX 27B Ch3 | 95 81 30 49 61 81 30 49 61 02 0b 2f 00 00 09 9f 00 c0 00 be 09 2f 13 87 07 70 9e 
12:24:21 I: RX 27B Ch23 | 95 81 30 49 61 81 30 49 61 02 0b 2f 00 00 09 9f 00 c0 00 be 09 2f 13 87 07 70 9e 
12:24:22 W: while retrieving data: last frame missing: Request Retransmit
12:24:22 I: TX 11B Ch3 | 15 81 30 49 61 84 10 66 54 83 a9 
12:24:23 W: while retrieving data: last frame missing: Request Retransmit
12:24:23 I: TX 11B Ch23 | 15 81 30 49 61 84 10 66 54 83 a9 
12:24:23 I: RX 23B Ch3 | 95 81 30 49 61 81 30 49 61 83 00 02 00 51 03 e8 00 a9 00 01 41 25 62 
12:24:23 I: RX 23B Ch23 | 95 81 30 49 61 81 30 49 61 83 00 02 00 51 03 e8 00 a9 00 01 41 25 62 
12:24:23 I: procPyld: cmd:  11
12:24:23 I: procPyld: txid: 0x95
12:24:23 I: Payload (42): 00 01 01 a6 01 16 04 95 01 c4 00 b6 03 35 00 00 0b 2f 00 00 09 9f 00 c0 00 be 09 2f 13 87 07 70 00 02 00 51 03 e8 00 a9 00 01 
webSerial, buffer overflow!
12:24:24 I: Mitte/ch0/Efficiency: 95.486 %
12:24:24 I: 
12:24:24 I: Inverter: 2
12:24:24 I: Unten/ch1/U_DC: 43.300 V
12:24:24 I: Unten/ch1/I_DC: 1.740 A
12:24:24 I: Unten/ch1/P_DC: 75.300 W
12:24:24 I: Unten/ch1/YieldDay: 155.000 Wh
12:24:24 I: Unten/ch1/YieldTotal: 2.764 kWh
12:24:24 I: Unten/ch1/Irradiation: 16.733 %
12:24:24 I: Unten/ch2/U_DC: 41.400 V
12:24:24 I: Unten/ch2/I_DC: 1.950 A
12:24:24 I: Unten/ch2/P_DC: 80.700 W
12:24:24 I: Unten/ch2/YieldDay: 190.000 Wh
12:24:24 I: Unten/ch2/YieldTotal: 3.180 kWh
12:24:24 I: Unten/ch2/Irradiation: 17.933 %
12:24:24 I: Unten/ch0/U_AC: 237.800 V
12:24:24 I: Unten/ch0/I_AC: 0.630 A
12:24:24 I: Unten/ch0/P_AC: 148.900 W
12:24:24 I: Unten/ch0/Q_AC: 0.100 var
12:24:24 I: Unten/ch0/F_AC: 49.990 Hz
12:24:24 I: Unten/ch0/PF_AC: 1.000 
12:24:24 I: Unten/ch0/Temp: 19.600 °C
12:24:24 I: Unten/ch0/ALARM_MES_ID: 1.000 
12:24:24 I: Unten/ch0/YieldDay: 345.000 Wh
12:24:24 I: Unten/ch0/YieldTotal: 5.944 kWh
12:24:24 I: Unten/ch0/P_DC: 156.000 W
12:24:24 I: Unten/ch0/Efficiency: 95.449 %
12:24:24 I: 
C: 2.780 A
12:24:24 I: Mitte/ch1/P_DC: 117.300 W
12:24:24 I: Mitte/ch1/YieldDay: 192.000 Wh
12:24:24 I: Mitte/ch1/YieldTotal: 2.863 kWh
12:24:24 I: Mitte/ch1/Irradiation: 26.067 %
12:24:24 I: Mitte/ch2/U_DC: 45.200 V
12:24:24 I: Mitte/ch2/I_DC: 1.820 A
12:24:24 I: Mitte/ch2/P_DC: 82.100 W
12:24:24 I: Mitte/ch2/YieldDay: 190.000 Wh
12:24:24 I: Mitte/ch2/YieldTotal: 2.463 kWh
12:24:24 I: Mitte/ch2/Irradiation: 18.244 %
12:24:24 I: Mitte/ch0/U_AC: 235.100 V
12:24:24 I: Mitte/ch0/I_AC: 0.810 A
12:24:24 I: Mitte/ch0/P_AC: 190.400 W
12:24:24 I: Mitte/ch0/Q_AC: 0.200 var
12:24:24 I: Mitte/ch0/F_AC: 49.990 Hz
12:24:24 I: Mitte/ch0/PF_AC: 1.000 
12:24:24 I: Mitte/ch0/Temp: 16.900 °C
12:24:24 I: Mitte/ch0/ALARM_MES_ID: 1.000 
12:24:24 I: Mitte/ch0/YieldDay: 382.000 Wh
12:24:24 I: Mitte/ch0/YieldTotal: 5.326 kWh
12:24:24 I: 

Error description

Wenn ich eine weile auf der Serial/Control Seite bleibe um mir die Log anzusehen, erscheint immer wieder Buffer Overflow und nach einer gewissen Zeit startet der WR neu. Bin ich auf einer anderen Seite z.B. die Live-Seite habe ich das Problem nicht. In den Logs selbst werden auch nur die Daten von zwei WR angezeigt und nicht von drei.

beegee3 commented 1 year ago

Das kann doch eigentlich nur die 'serial' Ausgabe sein (Text wird zu lang). @lumapu Vielleicht vor con.value += e.data.replace(/\<rn\>/g, '\r\n'); ab einer gewissen Textlänge den Anfang abschneiden.

stefan123t commented 1 year ago

Ich lese immer wieder webSerial, buffer overflow!