On transmit, power display is low on all band. These are the readings on my
system (SN:1002)
Ext SWR Meter DISP
Band PWR-IN SWR-IN PWR-OUT PWR
160 4.60 1.32 48.00 38.00
80 4.90 1.18 60.00 45.00
40 4.80 1.12 54.00 38.00
30 4.80 1.08 52.00 36.00
20 4.70 1.08 57.00 39.00
17 4.60 1.06 57.00 39.00
15 4.80 1.06 55.00 35.00
12 4.80 1.07 46.00 29.00
10 4.60 1.06 35.00 20.00
6 4.50 1.05 34.00 20.00
Power out column was measured using a 5W-2012 Digital SWR Meter, with the
amplifier into a 50 Ohm dummy load.
Not sure about the present code. I have used a calibration factor per band to
bring the power measured by the bridge closer actual output power.
Replacing the 1N914s in the SWR bridge with 1N5711 diodes should also improve
linearity.
Javier
Original issue reported on code.google.com by KC2QII@gmail.com on 26 Aug 2012 at 12:15