I ran whole set processing on a series of images, and the results for image 13 to image 14 were exactly twice the displacement of all the other image pairs (all others were correct). This tells me somewhere that an image was skipped (i.e., it actually processed image 13 to 15 or image 12 to 14). Any thoughts on what could cause this @kp-121 ?
I ran whole set processing on a series of images, and the results for image 13 to image 14 were exactly twice the displacement of all the other image pairs (all others were correct). This tells me somewhere that an image was skipped (i.e., it actually processed image 13 to 15 or image 12 to 14). Any thoughts on what could cause this @kp-121 ?