Closed GoogleCodeExporter closed 9 years ago
Please check your clock synchronization. If that doesn't help, provide a long
enough log (from PWM start until the incident occurs) at TRACE level and steps
to reproduce.
Original comment by menno.pi...@gmail.com
on 27 Nov 2013 at 7:21
This is most likely working as designed. If a session is used that is still a
valid tomcat session, but hasn't served a page since the maximum idle time ago,
then you'll see this error. Most likely reasons for the tomcat session to
still be valid is that a resource (perhaps under /public/resources/* has been
retrieved (keeping the tomcat-level session active) but not a main pwm page.
This is either due to customiation or a bug, and we would need a log trace to
see this. The other reason is a tomcat shutdown/restart which preserves old
sessions until the server has been up and they idle out again.
Original comment by jrivard
on 2 Dec 2013 at 7:16
This happened for me during the configuration process. Is there a way to get
around this behavior?
Original comment by da...@optionmetrics.com
on 3 Dec 2013 at 9:53
This issue has been resolved in the current nightly builds.
Original comment by jrivard
on 3 Apr 2014 at 7:32
I am seeing this error as well I have tried v1.7 and 1.7.1 and in both I see
the issue
A security violation has occurred. Please try again later. { 5063
ERROR_SECURITY_VIOLATION (current network address 'xxx.xxx.66.205' has changed
from original network address 'xxx.xxx.15.134') }
This issue only occurs after idle session expires and redirected to anther page.
User is unabled to access pwm page until browser cache is cleared
Original comment by lilia...@gmail.com
on 30 Sep 2014 at 3:10
Original issue reported on code.google.com by
g...@sandydproductions.com
on 27 Nov 2013 at 7:11