mag1024 / bosch-alarm-homeassistant

Integration for Bosch Alarm panels that use the mode2 protocol: Solution, B/G series, AMAX
26 stars 4 forks source link

Arming broken on latest release #9

Closed sanjay900 closed 1 year ago

buzurk26 commented 1 year ago

Commands look to be broken, Alarm going to disconnected state in HA

Logs showing entries like this image

buzurk26 commented 1 year ago

After HA reboot image

sanjay900 commented 1 year ago

Having a look now with my panels, i have two 3000's and a b series, so ill see if they exhibit the same issues

sanjay900 commented 1 year ago

Is there anything else in the logs?

sanjay900 commented 1 year ago

Was your panel armed at this point?

sanjay900 commented 1 year ago

I have just pushed a quick change to catch that specific error, I still appear to be able to arm so im not really sure whats going on there

sanjay900 commented 1 year ago

Are you using a code for arming?

sanjay900 commented 1 year ago

Okay, i did find a bug where if you set an integer code for arming / disarming, that wasnt working, have pushed a fix for that, are things working for you now?

buzurk26 commented 1 year ago

Do i just update via HACs ?

sanjay900 commented 1 year ago

yeah, you may have to tell HACS to update information so it finds the new version

sanjay900 commented 1 year ago

did it work?

buzurk26 commented 1 year ago

Hi, Looks to be working now since update - Thank you!