MKS Robin is a powerful 32-bit 3D printer control board with STM32F103ZET6 . Support Marlin2.0. Support MKS Robin TFT24/28/32... Screens. The motherboard integrates 5 AXIS interface, hot bed, 2 heating heads, 3 NTC100K, 2 MAX31855.Support MKS Robin WIFI for cloud printing.Supports firmware update by SD card…
https://es.aliexpress.com/item/32757129463.html?spm=a219c.12010612.8148356.9.5fc165f4oDUfFM
131 stars 129 forks source link

Robin nano err1 extruder issue #181

Closed Richiew07 closed 4 years ago

Richiew07 commented 4 years ago

I've just installed the robin nano and tft35 on a Ender 3. I am having an err1 when I try and heat the extruder, the extruder will will only stay at about 22/23 where as the bed starts shooting up and when it gets to around 100 it will show err1. The bed doesn't appear to get ho either. Any ideas?

makerbase-mks commented 4 years ago

Hi! Robin Nano error type

Err1: The thermal bed exceeds the maximum temperature limit, please check whether the thermal interface is shorted; Err2: The nozzle exceeds the maximum temperature limit, please check whether the thermal interface is shorted; Err3: The hot bed exceeds the minimum temperature limit, please check whether the thermal interface is disconnected; Err4: The nozzle exceeds the minimum temperature limit, please check whether the thermal interface is disconnected; Err5: The heating of the nozzle fails. If the nozzle does not reach the set temperature difference within the set time, an error will be reported; please check the configuration file settings or check whether the power supply is sufficient; Err6: The heating of the hot bed fails. If the hot bed reaches the set temperature difference within the set time, an error will be reported; please check the configuration file settings or check whether the power supply is sufficient; Err7: Thermal runaway; when the temperature reaches the target temperature, the current temperature is lower than the target temperature value within the set time and exceeds the set temperature, an error will be reported; please check whether the thermal sensitivity is normal or whether the PID value is appropriate.