Closed Flo082002 closed 4 years ago
Good Question, Sorry, I don't know the answer either. I would like to expand this issue. The documentation explaining ALL of the jumpers is missing from Datasheet and documentation for the SGen_L. Can it please be added. Thank you. Drew
Hi! @Flo082002 @DrewBatchelor The DIAG signal is suitable for the TMC2209 / TMC2130 SENSORLESS_HOMING function. Why do we keep jumpers? When you no longer use the SENSORLESS_HOMING function, the signal from DIAG will interfere with the signal of the mechanical switch, resulting in no return to zero operation or being affected, so you need to remove the jumpers on DIAG. When you use the SENSORLESS_HOMING function, you only need to use the jumper short circuit
What is the function of the X_Diag, Y_Diag, Z_Diag, E0_Diag and E1_Diag jumpers? They are not connected in the circuit diagram. What are they for? Regards Flo S