Open tjengbudi opened 5 months ago
yes, this looks strange. are the heightmap almost the same for each bed mesh? could you paste some data here from the console?
suddenly the bd sensor cannot response. i do not why. now i event cannot get Z HOME... check it first and confirm after will report you
@markniu i check the cable and change the SDA to used EXP1 port and it still cannot receive any data. what i must to do?
Both the SCL and SDA pins are changed to EXP1? make sure the 2 GND wires are connected to the mainboard
the scl still used probe/servos pin. i checked with m119 the z always open i put metal and the light in the bdsensor's led is on, but m119 return z still open
On Fri, May 17, 2024 at 2:10 PM Mark @.***> wrote:
Both the SCL and SDA pins are changed to EXP1? make sure the 2 GND wires are connected to the mainboard
— Reply to this email directly, view it on GitHub https://github.com/markniu/Bed_Distance_sensor/issues/139#issuecomment-2116898148, or unsubscribe https://github.com/notifications/unsubscribe-auth/AAXGEP2BUFOF2JUD27MKRBDZCWUNTAVCNFSM6AAAAABH3FHHLWVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDCMJWHA4TQMJUHA . You are receiving this because you authored the thread.Message ID: @.***>
M102 S-1 return nothing?
it is return "BDsensorVer:V1.1 pandapi3d.com ,switch_mode=0,collision_homing=0,collision_cal=0"
On Fri, May 17, 2024 at 2:24 PM Mark @.***> wrote:
M102 S-1 return nothing?
— Reply to this email directly, view it on GitHub https://github.com/markniu/Bed_Distance_sensor/issues/139#issuecomment-2116917788, or unsubscribe https://github.com/notifications/unsubscribe-auth/AAXGEP3ZVUDRH22HHWC7WBTZCWWBRAVCNFSM6AAAAABH3FHHLWVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDCMJWHEYTONZYHA . You are receiving this because you authored the thread.Message ID: @.***>
M102 S-2 always return " BDsensor:Out of measure Range or too close to the bed"
Calibrate again
how to calibrate. i cannot homing for Z. it never detect my bed. and crash after i homing. force manual?
Calibrate again
BDsensor is too far from the bed:1015
how to calibrate. i cannot homing for Z. it never detect my bed. and crash after i homing. force manual?
yes ,use the manual and SET_KINEMATIC_POSITION , M102 S-6
and then check the data after M102 S-5
how to calibrate. i cannot homing for Z. it never detect my bed. and crash after i homing. force manual?
yes ,use the manual and SET_KINEMATIC_POSITION , M102 S-6
after i send M102 S-6 i got BDsensor is too far from the bed:1015
after i send M102 S-5 i got
" 02:46:26 pm 1015 02:46:26 pm 1015 02:46:26 pm 1015 02:46:26 pm 979 02:46:26 pm 979 02:46:26 pm 979 02:46:26 pm 964 02:46:26 pm 943 02:46:26 pm 923 02:46:26 pm 902 02:46:26 pm 882 02:46:26 pm 860 02:46:26 pm 982 02:46:26 pm 977 02:46:26 pm 950 02:46:26 pm 922 02:46:26 pm 895 02:46:26 pm 907 02:46:26 pm 879 02:46:26 pm 686 02:46:26 pm 663 02:46:26 pm 641 02:46:26 pm 617 02:46:26 pm 594 02:46:26 pm 569 02:46:26 pm 545 02:46:26 pm 519 02:46:26 pm 396 02:46:26 pm 265 02:46:26 pm 587 02:46:26 pm 588 02:46:26 pm 558 02:46:26 pm 528 02:46:26 pm 357 02:46:26 pm 306 02:46:26 pm 280 02:46:26 pm 252 02:46:26 pm 222 02:46:26 pm 195 02:46:26 pm 175 02:46:26 pm M102 S-5 "
the data looks right. btw the led on represent that it is in the measure range but not mean it is triggered for the z axis
and now it suddenly "BDsensor is too far from the bed:1015" again
you can comment out the no_stop_probe
in the section BDsensor, and send M102 S-2 to check the actual distance after it stopped by that error
after some touch here and touch there... it is working again. check cable with multitester. it is connected ok
after plug again and test it is run but the result is amaizing
M102 S-2 fave result "0.42mm"
is the data returned by M102 S-2 almost the same after very
G28
G1 Z1
M102 S-2
after idle... it stop working again... frustrated what happened with this sensor
it crash after i sent g28
after hard reboot
03:48:53 pm 0.42mm 03:48:40 pm G28 G1 Z1 M102 S-2 03:48:32 pm 0.42mm 03:48:19 pm G28 G1 Z1 M102 S-2 03:48:10 pm 0.41mm 03:47:58 pm G28 G1 Z1 M102 S-2
0.41 mm 0.42 mm 0.42 mm trying 3 times
trying check and meassure without changing the height at all
the result very strange " 03:53:00 pm 0.44mm 03:53:00 pm M102 S-2 03:52:56 pm 0.44mm 03:52:56 pm M102 S-2 03:52:56 pm 1.03mm 03:52:56 pm M102 S-2 03:52:55 pm 1.03mm 03:52:55 pm M102 S-2 03:52:55 pm 1.03mm 03:52:55 pm M102 S-2 03:52:54 pm 1.03mm 03:52:54 pm M102 S-2 03:52:53 pm 1.03mm 03:52:53 pm M102 S-2 03:52:52 pm 1.03mm 03:52:52 pm M102 S-2 03:52:52 pm 1.03mm 03:52:52 pm M102 S-2 03:52:52 pm 1.03mm 03:52:52 pm M102 S-2 03:52:51 pm 1.03mm 03:52:51 pm M102 S-2 03:52:51 pm 1.03mm 03:52:51 pm M102 S-2 03:52:51 pm 1.03mm 03:52:51 pm M102 S-2 03:52:51 pm 1.03mm 03:52:51 pm M102 S-2 03:52:50 pm 1.03mm 03:52:50 pm M102 S-2 03:52:50 pm 1.03mm 03:52:50 pm M102 S-2 03:52:50 pm 1.03mm 03:52:50 pm M102 S-2 03:52:50 pm 1.03mm 03:52:50 pm M102 S-2 03:52:49 pm 1.03mm 03:52:49 pm M102 S-2 03:52:49 pm 1.03mm 03:52:49 pm M102 S-2 03:52:48 pm 1.03mm 03:52:48 pm M102 S-2 03:52:48 pm 1.03mm 03:52:48 pm M102 S-2 03:52:47 pm 1.03mm 03:52:47 pm M102 S-2 03:52:47 pm 1.03mm 03:52:47 pm M102 S-2 03:52:46 pm 1.03mm 03:52:46 pm M102 S-2 03:52:45 pm 1.03mm 03:52:45 pm M102 S-2 03:52:44 pm 1.03mm 03:52:44 pm M102 S-2 03:52:43 pm 1.03mm 03:52:43 pm M102 S-2 03:52:42 pm 1.03mm 03:52:42 pm M102 S-2 03:52:41 pm 0.99mm 03:52:41 pm M102 S-2 03:52:29 pm 0.99mm 03:52:29 pm M102 S-2 "
it can changing by him self from 0.99 --> 1.03 -->0.44
must i reflash it ?
I suspend that there is a hardware problem maybe the cable EMI from other wires. where and when do you purchase this v1.1 . I would like to send you a new one, you can send me your shipping address to my email niujl123@sina.com
did the hotend heat? if the hotend too close it maybe heat the coil
it can changing by him self from 0.99 --> 1.03 -->0.44
No, cold bed...
On Fri, May 17, 2024, 4:14 PM Mark @.***> wrote:
did the hotend heat?
it can changing by him self from 0.99 --> 1.03 -->0.44
— Reply to this email directly, view it on GitHub https://github.com/markniu/Bed_Distance_sensor/issues/139#issuecomment-2117105683, or unsubscribe https://github.com/notifications/unsubscribe-auth/AAXGEP6I4UI77ZWAPOYCOTLZCXC7JAVCNFSM6AAAAABH3FHHLWVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDCMJXGEYDKNRYGM . You are receiving this because you authored the thread.Message ID: @.***>
I suspend that there is a hardware problem maybe the cable EMI from other wires. where and when do you purchase this v1.1 . I would like to send you a new one, you can send me your shipping address to my email niujl123@sina.com
already sent please take a look
after install bd sensor and place mesh bed for 30 point to check i got strange result. is this normal?