21esc12 commented 12 years ago

when running see_refl at the end of the final_test, pulses on Nhit 100 and 20 remain after the test is complete. It will trigger in and out.

I tried:

1)mtc_init = still happening 2)crate_init -c 12 -s 4 = still happening 3)crate_init -c 12 -s 4 -x -v = still happening 4) sm_reset -c 12 = still happening 5)tryed all 3 buttons on the back of the XL3 ( was not sure witch one was the restart) = still happening

It seemed after idealing for about 15 mins it went away on it own??

mastbaum commented 12 years ago

@bonventre