Open stephanmae opened 4 years ago
Hi there, I am trying to connect to S7 and open the Q1 on a logo. Therefore, I am writing one bit which should trigger the Q1 to open. But it does not work, connection succeedes, writing even succeeds, but the relais does not get closed:
Does anyone has an idea?
var snap7 = require('node-snap7');
var s7client = new snap7.S7Client(); s7client.ConnectTo('192.168.1.2', 0, 2, function(err) { if(err) return console.log(' >> Connection failed. Code #' + err + ' - ' + s7client.ErrorText(err));
// Read the first byte from PLC process outputs... console.log('reading q1'); var read = s7client.ABRead(1, 1); console.log(read); // open console.log('writing q1'); const buffer = new Buffer([0x01]); var result = s7client.ABWrite(1, 1, buffer, function(err) { if(err) return console.log(' >> ABRead failed. Code #' + err + ' - ' + s7client.ErrorText(err)); console.log(err); });
console.log(result); });
Many thanks!
Hi there, I am trying to connect to S7 and open the Q1 on a logo. Therefore, I am writing one bit which should trigger the Q1 to open. But it does not work, connection succeedes, writing even succeeds, but the relais does not get closed:
Does anyone has an idea?
var snap7 = require('node-snap7');
var s7client = new snap7.S7Client(); s7client.ConnectTo('192.168.1.2', 0, 2, function(err) { if(err) return console.log(' >> Connection failed. Code #' + err + ' - ' + s7client.ErrorText(err));
console.log(result); });