Open demirschmid61 opened 3 weeks ago
@matth-x There is a little update on this problem
I followed the process to crosscheck
Please have a look at the logs
/----------------------LOGS ----------------------------/ [MO] info (main.cpp:3450): OCPP Connected to url: /ABCD [MO] Send: [2,"1000000","BootNotification",{"chargePointModel":"AC","chargePointSerialNumber":"ABCD","chargePointVendor":"ABCD","firmwareVersion":"0.0.7"}]
[MO] Recv: WS pong [MO] Recv: [3,"1000000",{"currentTime":"2024-09-03T06:25:55.195996200Z","interval":900,"status":"Accepted"}] [MO] info (BootNotification.cpp:83): request has been Accepted [MO] info (StatusNotification.cpp:50): New status: Available (connectorId 0) [MO] info (StatusNotification.cpp:50): New status: Available (connectorId 1) [MO] Send: [2,"1000001","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"Available","timestamp":"2024-09-03T06:25:55.199Z"}] [MO] Recv: [3,"1000001",{}] [MO] Send: [2,"1000002","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"Available","timestamp":"2024-09-03T06:25:55.409Z"}] [MO] Recv: [3,"1000002",{}]
Hello @matth-x,
I did 146 ocpp transactions for 147th transaction the RemoteStartTransaction gets rejected and the connector status shows Preparing without a gun connection. Please have a look at the logs
/----------------------LOGS with connector problem and Reject remote requst----------------------------/
[MO] Send: [2,"1000000","BootNotification",{"chargePointModel":"AC","chargePointSerialNumber":"ABCD","chargePointVendor":"ABCD","firmwareVersion":"0.0.7"}] [MO] Recv: WS pong [MO] Recv: [3,"1000000",{"currentTime":"2024-08-27T09:19:32.876446300Z","interval":900,"status":"Accepted"}] [MO] info (BootNotification.cpp:91): request has been Accepted [MO] info (StatusNotification.cpp:52): New status: Available (connectorId 0) [MO] info (StatusNotification.cpp:52): New status: Preparing (connectorId 1) [MO] Send: [2,"1000001","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"Available","timestamp":"2024-08-27T09:19:32.887Z"}] [MO] Recv: [3,"1000001",{}] [MO] Send: [2,"1000002","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"Preparing","timestamp":"2024-08-27T09:19:32.888Z"}] [MO] Recv: [3,"1000002",{}] [MO] Recv: [2,"1954ecad-cc47-46f3-9336-af2e59128563","RemoteStartTransaction",{"connectorId":1,"idTag":"BAEDFCDE"}] [MO] info (RemoteStartTransaction.cpp:114): No connector to start transaction [MO] Send: [3,"1954ecad-cc47-46f3-9336-af2e59128563",{"status":"Rejected"}]
/---------------------- ----------------- ----------------------------/
Also, sharing the JSON file data of the following files available in ESP32
- /bootstats.jsn {"bootNr":170,"lastSuccess":169}
- /client-state.jsn {"head":{"content-type":"ocpp_config_file","version":"2.0"},"configurations":[{"type":"bool","key":"Cst_AVAIL_CONN_0","value":true},{"type":"bool","key":"Cst_AVAIL_CONN_1","value":true},{"type":"string","key":"MicroOcppVersion","value":"1.1.0"}]}
- /ocpp-config.jsn {"head":{"content-type":"ocpp_config_file","version":"2.0"},"configurations":[{"type":"bool","key":"Cst_PreBootTransactions","value":false},{"type":"int","key":"ConnectionTimeOut","value":30},{"type":"int","key":"MinimumStatusDuration","value":0},{"type":"bool","key":"StopTransactionOnInvalidId","value":true},{"type":"bool","key":"StopTransactionOnEVSideDisconnect","value":true},{"type":"bool","key":"LocalPreAuthorize","value":false},{"type":"bool","key":"LocalAuthorizeOffline","value":true},{"type":"bool","key":"AllowOfflineTxForUnknownId","value":false},{"type":"bool","key":"Cst_SilentOfflineTransactions","value":false},{"type":"int","key":"Cst_AuthorizationTimeout","value":20},{"type":"bool","key":"Cst_FreeVendActive","value":false},{"type":"string","key":"Cst_FreeVendIdTag","value":""},{"type":"bool","key":"Cst_TxStartOnPowerPathClosed","value":false},{"type":"int","key":"HeartbeatInterval","value":900},{"type":"bool","key":"LocalAuthListEnabled","value":true},{"type":"int","key":"ResetRetries","value":2},{"type":"string","key":"MeterValuesSampledData","value":"Voltage,Current.Import,Energy.Active.Import.Register,Power.Active.Import,Temperature"},{"type":"int","key":"MeterValueSampleInterval","value":15},{"type":"string","key":"StopTxnSampledData","value":""},{"type":"string","key":"MeterValuesAlignedData","value":"Energy.Active.Import.Register,Power.Active.Import"},{"type":"string","key":"StopTxnAlignedData","value":""},{"type":"int","key":"Cst_MeterValueCacheSize","value":1},{"type":"int","key":"ClockAlignedDataInterval","value":0},{"type":"bool","key":"Cst_MeterValuesInTxOnly","value":true},{"type":"bool","key":"Cst_StopTxnDataCapturePeriodic","value":false}]}
- /opstore.jsn {"head":{"content-type":"ocpp_config_file","version":"2.0"},"configurations":[{"type":"int","key":"Cst_opBegin","value":294}]}
- /reservations.jsn {"head":{"content-type":"ocpp_config_file","version":"2.0"},"configurations":[{"type":"int","key":"cid_0","value":-1},{"type":"string","key":"expdt_0","value":""},{"type":"string","key":"idt_0","value":""},{"type":"int","key":"rsvid_0","value":-1},{"type":"string","key":"pidt_0","value":""}]}
- /txstore.jsn {"head":{"content-type":"ocpp_config_file","version":"2.0"},"configurations":[{"type":"int","key":"txBegin_0","value":0},{"type":"int","key":"txEnd_0","value":0},{"type":"int","key":"txBegin_1","value":144},{"type":"int","key":"txEnd_1","value":148}]}
I reset the charger many times, even if it shows preparing and rejects the remoteStartTransaction request.
Can you please tell me where it went wrong, or is there anything I need to set or reset?