melvinstorbacka / REACLIB-SOLNAR

1 stars 1 forks source link

Check binding energy/mass excess converter #9

Closed melvinstorbacka closed 10 months ago

melvinstorbacka commented 10 months ago

There was no problem, and furthermore it is not needed, since the $Q$-value can be obtained as $$Q = \Delta M_i - \Delta M_f,$$ and the Q-value for each calculation is $$Q = \Delta M_i - \Delta M_f + \delta Q.$$

$Q$-values now correspond satisfactorily to $Q$-values in AME20 ($S_n$ of $^AX$ = $Q$-value of $^{A-1}X$)

Completed 11/12/2023