meshtastic / firmware

Meshtastic device firmware
https://meshtastic.org
GNU General Public License v3.0
3.58k stars 891 forks source link

[Bug]: 2.5.1 random reboots on RAK and Station G2 #4833

Closed smarsh-biolinq closed 1 month ago

smarsh-biolinq commented 1 month ago

Category

Hardware Compatibility, BLE

Hardware

Rak4631, Station G2

Firmware Version

2.5.1

Description

On both units, i completely reset the install, and it will randomly reboot. I notice it when on BLE, but i am not certain it is not happening when not connected to BLE. Had to revert back to 2.5.0

Relevant log output

No response

remowashere commented 1 month ago

Same on Seeed Sensecap T1000, T-Echo and Heltec T114. Will test some ESP32's as well, but these three reboot every couple of minutes. Reboots only (seems to) happen when connected via BT (latest iOS app).

thebentern commented 1 month ago

Feel like trying an experimental build? This resolved the issue for me. https://github.com/meshtastic/firmware/actions/runs/10999713818

smarsh-biolinq commented 1 month ago

Feel like trying an experimental build? This resolved the issue for me. https://github.com/meshtastic/firmware/actions/runs/10999713818

Hi There, Thank you! i was looking at that build and was thinking of trying it as well... Thanks for the tip! BTW, aren't they all experimental builds at this point? ;-)

remowashere commented 1 month ago

Feel like trying an experimental build? This resolved the issue for me. https://github.com/meshtastic/firmware/actions/runs/10999713818

Can confirm, on all mentioned devices this firmware works without a problem 👍

thebentern commented 1 month ago

Closed with #4834