metbril / home-assistant-config

🏠 My Home Assistant configuration
MIT License
25 stars 2 forks source link

Home Assistant Alert: Avoid 700 Series Z-Wave Controllers #72

Closed metbril closed 8 months ago

metbril commented 2 years ago

Avoid 700 Series Z-Wave Controllers
https://ift.tt/3GDZFMt

While 700 series Z-Wave Controllers are supported by Z-Wave JS, the firmware for those devices presently has a bug that can cause the mesh to be flooded on some networks and the controller to become unresponsive. At present, all 700 series controllers share the same firmware and are subject to this bug. Z-Wave JS and several manufacturers have notified Silicon Laboratories and are awaiting resolution.

Workaround

Users should avoid upgrading to 700 series controllers at this time, if possible. Users that have already upgraded and are experiencing the effects of this bug should consider downgrading to a 500 series controller. This can be done for many controllers by backing up the 700 series controller and restoring the resulting backup to the prior controller, using Zwavejs2mqtt. The 500 series controller must be on Z-Wave SDK 6.61 or higher, so a firmware upgrade may be required. Zwavejs2mqtt >6.3.0 is also required.

Users who do not have a second, 500 series controller should configure their Z-Wave devices to avoid frequent messages, such as energy monitors that update their values every few seconds. While this does not resolve the issue for all users, many with frequently quiet meshes have been able to avoid the effects of this bug.



via Home Assistant - Alerts https://ift.tt/3uMr2yB
January 17, 2022 at 01:00PM

metbril commented 1 year ago

Not sure what I use. Still need to find out.