C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\out\terminal.html
at Module._resolveFilename (internal/modules/cjs/loader.js:887)
at Function.o._resolveFilename (electron/js2c/renderer_init.js:33)
at Module._load (internal/modules/cjs/loader.js:732)
at Function.f._load (electron/js2c/asar_bundle.js:5)
at Function.o._load (electron/js2c/renderer_init.js:33)
at Module.require (internal/modules/cjs/loader.js:959)
at require (internal/modules/cjs/helpers.js:88)
at new WindowsPtyAgent (C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\lib\windowsPtyAgent.js:40)
at new WindowsTerminal (C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\lib\windowsTerminal.js:50)
at Object.spawn (C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\lib\index.js:28)
C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\lib\windowsPtyAgent.js:45 Uncaught Error: \?\C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\build\Release\conpty.node is not a valid Win32 application.
\?\C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\build\Release\conpty.node
at process.func [as dlopen] (electron/js2c/asar_bundle.js:5)
at Object.Module._extensions..node (internal/modules/cjs/loader.js:1138)
at Object.func [as .node] (electron/js2c/asar_bundle.js:5)
at Module.load (internal/modules/cjs/loader.js:935)
at Module._load (internal/modules/cjs/loader.js:776)
at Function.f._load (electron/js2c/asar_bundle.js:5)
at Function.o._load (electron/js2c/renderer_init.js:33)
at Module.require (internal/modules/cjs/loader.js:959)
at require (internal/modules/cjs/helpers.js:88)
at new WindowsPtyAgent (C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\lib\windowsPtyAgent.js:36)
Environment details
Issue description
innerError Error: Cannot find module '../build/Debug/conpty.node' Require stack:
C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\lib\windowsPtyAgent.js:45 Uncaught Error: \?\C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\build\Release\conpty.node is not a valid Win32 application. \?\C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\build\Release\conpty.node at process.func [as dlopen] (electron/js2c/asar_bundle.js:5) at Object.Module._extensions..node (internal/modules/cjs/loader.js:1138) at Object.func [as .node] (electron/js2c/asar_bundle.js:5) at Module.load (internal/modules/cjs/loader.js:935) at Module._load (internal/modules/cjs/loader.js:776) at Function.f._load (electron/js2c/asar_bundle.js:5) at Function.o._load (electron/js2c/renderer_init.js:33) at Module.require (internal/modules/cjs/loader.js:959) at require (internal/modules/cjs/helpers.js:88) at new WindowsPtyAgent (C:\Users\username\Desktop\ServerTool\releasebuilds\ServerTool-win32-ia32\resources\app\node_modules\node-pty\lib\windowsPtyAgent.js:36)