mikejohnson51 / hydrofab

Hydrofabric Fabricator
Creative Commons Zero v1.0 Universal
9 stars 4 forks source link

Disconnected Network errors in aggregation #7

Closed mikejohnson51 closed 2 years ago

mikejohnson51 commented 2 years ago

In tracking down #6, I found that ~34 flowlines in VPU01 are disconnected from the network.

These include:

[1]   695  2256  4671  4677  4792  4890  5288
[8]  5618  5951  6115  8856  8912  9230  9421
[15]  9976 10432 11572 12114 12131 12132 13970
[22] 14388 14686 15241 15346 15363 15914 16354
[29] 16676 16838 17798 18119 18147 18331

example:

image

mikejohnson51 commented 2 years ago

This is occurring in collapse_headwaters when 2 a small headwater catchment sits between two large enough catchments where one flys water over the small one.

mikejohnson51 commented 2 years ago

New result for above area:

image

mikejohnson51 commented 2 years ago

Following this, there are 5 remaining disconnected IDs:

These are:

7725 12169 18727 22814 23489

Example:

image