Closed knc6 closed 1 year ago
Hi @knc6 ,
Thanks for your interest in our code!
e/N_mae
is the per-atom error (i.e. energy units/atom). Quoting the notebook:
The units of the reference data are in kcal/mol and A. If you're more familiar with eV, remember 1 kcal/mol is chemical accuracy and is approximately 43 meV
You can see that 0.0225 kcal/mol * 43 meV / (kcal/mol) is about 1 meV.
configs/example.yaml
as a starting point.
Thanks for developing nequip and sharing the colab tutorial, which is very helpful.
The notebook mentions "We see that the model has converged to an energy accuarcy < 1meV/atom and a force accuracy of approx. 40 meV/A within 5 minutes and trained on only 100 samples."
1) Its unclear to me which number is referred to in this statement. Is it the e_mae e/N_mae?
2) Is there any config file to reproduce the publication results from the original nequip paper? Perhaps this yaml file?