mkaiser / Sungrow-SHx-Inverter-Modbus-Home-Assistant

Sungrow SH Integration for Home Assistant for SH3K6, SH4K6, SH5K-20, SH5K-V13, SH3K6-30, SH4K6-30, SH5K-30, SH3.RS, SH3.6RS, SH4.0RS, SH5.0RS, SH6.0RS, SH5.0RT, SH6.0RT, SH8.0RT, SH10RT, SH5.0RT-20, SH6.0RT-20, SH8.0RT-20, SH10RT-20, SH5.0RT-V112, SH6.0RT-V112, SH8.0RT-V112, SH10RT-V112, SH5.0RT-V122, SH6.0RT-V122, SH8.0RT-V122, SH10RT-V122, SH4.6R
305 stars 79 forks source link

Updated inverter state sensor to support a value of 0x0000 for Running #207

Closed ABredhauer closed 7 months ago

ABredhauer commented 7 months ago

Latest Sungrow Modbus doc indicates that either 0x0000 or 0x0040 are valid values for the Running state. SH10RS returns 0x0000 Relates to #184

mkaiser commented 7 months ago

thanks!