Sungrow SH Integration for Home Assistant for SH3K6, SH4K6, SH5K-20, SH5K-V13, SH3K6-30, SH4K6-30, SH5K-30, SH3.RS, SH3.6RS, SH4.0RS, SH5.0RS, SH6.0RS, SH5.0RT, SH6.0RT, SH8.0RT, SH10RT, SH5.0RT-20, SH6.0RT-20, SH8.0RT-20, SH10RT-20, SH5.0RT-V112, SH6.0RT-V112, SH8.0RT-V112, SH10RT-V112, SH5.0RT-V122, SH6.0RT-V122, SH8.0RT-V122, SH10RT-V122, SH4.6R
375 stars 95 forks source link

Exporting Power not working #57

Closed andi-blafasl closed 1 year ago

andi-blafasl commented 1 year ago

After a few weeks with very little sun, today my battery was fully charged and the Inverter (SH6.0RT connected directly via eth, not through winet-s) started exporting power. But in HA there is no info about that. The Binary Sensor did not show and the exporting value is always zero. Here's a screenshot from the day: image as you can see, binary sensor for importing is working as expected. Any Ideas what's going wrong?

mkaiser commented 1 year ago

Are you using the latest version? I recently made some changes, when the running_state is not available.

Can you check the version and also the value of running_state?

mkaiser commented 1 year ago

Also please check, if there is some trouble with sensors under Settings --> Statistics

GrandAmmor commented 1 year ago

I had the same problem and fixed it with the update (230206).

At the moment sensor.meter_active_power shows unavailable for me. sensor.meter_active_power_raw works well in my evcc config.

andi-blafasl commented 1 year ago

I'm on version 2023-01-26, which was the latest at the time of posting 😄 Will do an update on the weekend.

AlexHG2 commented 1 year ago

Updated yesterday to version "2023-02-12". The result for export unfortunately still remains at "0". Export_power_raw have results.

No issues with Statistics:

image
andi-blafasl commented 1 year ago

Did the update to 2023-02-12 yesterday night and today it's very sunny. Export Power is now working for me: image

image

Importing is not shown because the battery was never empty the last days.

mkaiser commented 1 year ago

Did the update to 2023-02-12 yesterday night and today it's very sunny. Export Power is now working for me: ![image]

nice - thank you for the feedback :)

AlexHG2

Updated yesterday to version "2023-02-12". The result for export unfortunately still remains at "0". Export_power_raw have results.

Can you give me more information? What is your inverter and what are the other values showing? Maybe post me screenshots of the PV tabs

elektrinis commented 1 year ago

Not sure if this is related, but I had some battery issues, and now it won't discharge. I can set it to charge in forced mode, and it will charge the battery from sun in self-consumption mode. But it will not discharge in forced mode, and will not run on battery in self-consumption mode. After a full charge to 100% it did hold my house on battery for an hour or so, and then it just moved to the grid. So the battery is sitting at 98% now and I'm waiting for sungrow support to answer...

But it does export fine when it's sunny and battery is full.

mkaiser commented 1 year ago

Not sure if this is related, but I had some battery issues, and now it won't discharge. I can set it to charge in forced mode, and it will charge the battery from sun in self-consumption mode. But it will not discharge in forced mode, and will not run on battery in self-consumption mode. After a full charge to 100% it did hold my house on battery for an hour or so, and then it just moved to the grid. So the battery is sitting at 98% now and I'm waiting for sungrow support to answer...

But it does export fine when it's sunny and battery is full.

I had that once, when I started playing with the modbus interface. After a factory reset of the inverter everything was smooth again.

Can you check the two "start power" values?

image

Another possibility could be that the battery is going to a calibration mode. Just read about that, never experienced myself

elektrinis commented 1 year ago

These two values are at zero. Not sure what this means, I thought it will not start charging/discharging until surplus/load is above this value? How did you factory-reset it? I can't find this in manual...

AlexHG2 commented 1 year ago

Did the update to 2023-02-12 yesterday night and today it's very sunny. Export Power is now working for me: ![image]

nice - thank you for the feedback :)

AlexHG2

Updated yesterday to version "2023-02-12". The result for export unfortunately still remains at "0". Export_power_raw have results.

Can you give me more information? What is your inverter and what are the other values showing? Maybe post me screenshots of the PV tabs

Good news, it s working now :-) I deleted the old config which i moved to a subfolder in the integrations dir as backup. Therefore the version fixed the issues also on my side. Thanks a lot!!

mkaiser commented 1 year ago

glad that it worked ! :)

mkaiser commented 1 year ago

before resetting, try to set the battery dis/charging start power values

The sungrow app annoyed me so much .... I spent 15 minutes searching for it. Then I implemented it in yaml. Can you check the last commits? image

I don't recall exactly, but I think I triggered a factory reset using the isolarcloud webinterface, logged in as installer and after some time I found a button for factory reset

mkaiser commented 1 year ago

sorry elektrinis, did not mean to close the issue, yet :)

dylan09 commented 1 year ago

If I remember correctly Sungrow recommends to set start charging and discharging power to a value > 0. My setting is 100W for both.

And Max SoC should be set to 100%. Set that the balancer could do their work. But I think thats not the reason why it is not working for you.

Have solved my last problem through complete inverter shutdown. Shut off AC, DC and battery (sequence depends on your setup). Than wait 10-15 minutes and restart.

mkaiser commented 1 year ago

yep, 100W for start values is reasonable.

Will increase the input for max SoC to 100 in the next commit

elektrinis commented 1 year ago

Changed this to 100W, no effect. Also could not find the reset function... will keep looking.

mkaiser commented 1 year ago

there was no activity here for a long time.

Do the issues still exist? if yes, please check if your inverter has the current firmware first and report if something changed, please