libmonome fail on disconnect of "series" edition grids #539

Closed markwheeler closed 4 years ago

markwheeler commented 6 years ago

When I unplug my gs128 I get a flood of callbacks on the grid key event with x, y and z values all coming in as 1. Using a varibright 256 I don't see the same issue. Minor but reproducible every time.

tehn commented 6 years ago

this is likely the same issue that is causing gs not to work with a (eurorack) usb switch between norns and earthsea/etc.

tehn commented 6 years ago

highly suspect #542

tehn commented 6 years ago

confirmed failing behavior with other mono-bright grids of the "series" generation/protocol

worth checking if libmonome is working properly for these older devices.

tested fine with a variety of newer (2012-on) "mext" protocol devices

no longer suspecting #542