monome / teletype

monome eurorack module
GNU General Public License v2.0
204 stars 84 forks source link

TR.TIME shorter than 11ms gets skipped by delay MODs #244

Open desolationjones opened 3 years ago

desolationjones commented 3 years ago

Please describe the bug.

Sufficiently short (<11ms) trigger time pings via delay MODs do not reliably execute trigger pings.

Please include the hash displayed at startup and the release of the software (e.g. "Teletype v2.0.1 5f838c9")

Latest v3.2 beta

What steps are required to reproduce the bug?

  1. TR.TIME 1 10
  2. DEL M: TR.P 1
tehn commented 3 years ago

this is a byproduct of the scheduler.

fix should be just to threshold the minimum time to 11.