mostafa-razavi / ITIC-paper

0 stars 0 forks source link

Fix uncertainties in VLE plots #19

Closed mostafa-razavi closed 5 years ago

mostafa-razavi commented 6 years ago

Rich said:

One subtle concern with Figures 17, 19, and 21 (Clausius-Clapeyron plots) is that the ITIC error bars are only plotted in the y-direction, i.e. vapor pressure. We also report uncertainties in the temperature. So there should really be error bars in the x- and y-directions. Similarly, in Fig 18, 20, and 22 you included the vapor density uncertainties in the x-direction, but omitted the temperature uncertainties in the y-direction on the vapor side (you did include them on the liquid side). The liquid density uncertainties are zero and so they are rightfully not plotted. Since you are going back to work on these anyways, I figured I would point this out now. Really this is not a big deal since the uncertainties are so small anyways.