RPM measurements wrong #1

Open msashlee opened 8 years ago

msashlee commented 8 years ago

Measurements read wrong when multiple fans are being measured.

msashlee commented 8 years ago

after review, measurements -seeeeeming- wrong seems to be a hardware issue.
The fans are same mfr, same box, however on read:

These fs do change depending on number fans attached

More investigation testing (an oscilliscope would be nice) needed.

msashlee commented 8 years ago

put the dwell (FREQFADEDELAY) between freq.begin & avail/reads

check docs on freq library and ensure read takes most recent or flush/mitigate this