When devices fail to configure properly, we need to provide the error code and a note that the device launch failed. Right now,
both spam the logs and messages. Not acceptable! An acceptable message looks like this for the pressure transducers:
04:33:24.57 [p515] Device stopping. 04:33:24.61 [ctl] Launch of object with ID p515 failed with code -1073807339.
The Meerstetters fail with a bunch of messages - one for each command.
We need to send just one message AND NOT ATTEMPT TO CONTACT THE DEVICE AFTER ONE FAILS WITH -1073807339
-1073807339
May have not been bypassing errors for Meerstetters... Should throw one and then just push past all other serial IO.
This is what a bad log looks like (400+ messages that look like this):
Is this still a problem?
When devices fail to configure properly, we need to provide the error code and a note that the device launch failed. Right now,
both spam the logs and messages. Not acceptable! An acceptable message looks like this for the pressure transducers:
The Meerstetters fail with a bunch of messages - one for each command.
We need to send just one message AND NOT ATTEMPT TO CONTACT THE DEVICE AFTER ONE FAILS WITH
-1073807339