mvalla / openhab-addons

Add-ons for openHAB
Eclipse Public License 2.0
24 stars 16 forks source link

Support for WHO=4, WHAT=21,22,23 #36

Closed Gozilla01 closed 5 years ago

Gozilla01 commented 5 years ago

Implement the commands: WHAT = 21,22,23 link You see:

Can we choose 1,2,3, summer, winter programs on the 3550 plant? Currently “active mode” displays only the state “Off and anti freeze” not the state “auto or manual” 2018-12-28 09: 55: 36.786 [WARN] [penwebnet.message.openMessageFactory] - ## openwebnet ## unsupported WHAT 1101 from frame 4 1101 # 0 ## 2018-12-28 09: 55: 36.830 [WARN] [penwebnet.message.OpenMessageFactory] - ## openwebnet ## unsupported WHAT 21 from frame 4 21 # 0 ## 2018-12-28 09: 55: 39.937 [WARN] [penwebnet.message.openMessageFactory] - ## openwebnet ## unsupported WHAT 22 from frame 4 22 # 0 ## 2018-12-28 09: 55: 36.860 [WARN] [penwebnet.message.OpenMessageFactory] - ## openwebnet ## unsupported WHAT 23 from frame 4 23 # 0 ##

mvalla commented 5 years ago

for WHO=4, these commands are: 21 Remote control enabled 22 At least one probe OFF 23 At least one probe in Anti Freeze which seem not so useful. What is the use-case?

Gozilla01 commented 5 years ago

@tagada you can answer Massimo?

weltraumbagger commented 5 years ago

sorry i don´t understand, the who=4 commands that massimo described i cannot imagine what they are usefull for. michese asked for the possibillity to switch between the 3 summer and 3 winter programms, that may be usefull for somebody. for example i use winterprogramm1 for normally, winterprogramm2 when in holiday, well thats nearly never :)

mvalla commented 5 years ago

since there was no positive feedback, these commands will not be implemented for the moment. This issue will be closed soon.

mvalla commented 5 years ago

closed as the is no clear use case associated to this support request

rinal13 commented 4 years ago

Hello mvalla, I was contributing for the heating control at the bticino binding v1 and I Implemented there these codes. But important for these codes is that these are not commands, these are status messages from the central temperature control. Which are for information quite useful. i.e 21 Remote control enabled means that the central temperature controller can be controlled remotely i.e. by some Touch screens or by the binding.