CEN scenarios are not detected by the binding when activated from Touchescreens TS 3.5" (H4890), TS 10" MH4893 and Domotica app, because they do not fully support short/long pressure.
Therefore they are not sending the second event (RELEASE_SHORT_PRESSURE: *15*N#1*where##).
CEN scenarios are not detected by the binding when activated from Touchescreens TS 3.5" (H4890), TS 10" MH4893 and Domotica app, because they do not fully support short/long pressure. Therefore they are not sending the second event (RELEASE_SHORT_PRESSURE:
*15*N#1*where##
).Since this is described as a limitation in the OWN specs, the binding should support this, so that CEN scenario activated from Touchscreens are correctly detected. https://community.openhab.org/t/bticino-openwebnet-adding-cen-commands-design/54142/119