mworion / MountWizzard4

Amateur astronomy imaging support tool with special support for 10micron mounts.
Apache License 2.0
21 stars 8 forks source link

Envornment data: Dew point and humidity reversed in direct sensor data #328

Closed Yazracor closed 1 year ago

Yazracor commented 1 year ago

Describe the bug I have connected a MGBoxv2 to the 10Micron Mount via serial and to the computer via USB/ASCOM. In the sensor tab, under "direct", humidity and dew point are reversed. In the "sensor" tab, it shows correctly.

To Reproduce Connect an MGBox to a 10Micron mount. Use "direct" sensor data.

Expected behavior Show the correct sensor data.

Desktop (please complete the following information):

mworion commented 1 year ago

Hi thanks for the hint, service release 3.2.1 will fix this. Michel