Pulsewidth and Global division setting no longer saved in v1.3 #51

Open 7dials opened 4 years ago

7dials commented 4 years ago

Hi, I recently tried updating to firmware version 1.3 but have had to revert to version 1.2.3 as I find the new version unusable due to the following issues.

This meant I had to reapply these setting every time I turned my modular back on and while the idea of user slots is attractive these issues make the unit unusable in a live situation.

patrickdowling commented 4 years ago

FWIW this came up in the thread on MW last week, I've put tentative fixes here: fix/misc_fix

It only later occurred to me to check the issues here. That's based off master, I'm not really current on which branch might be more up to date.

SimonKunz commented 3 years ago

@patrickdowling Thank you for publishing your fixes. Just one question: will your fixed version of the firmware keep my calibration settings on the t_u when I install it like described here?

Thank you!

patrickdowling commented 3 years ago

Yes, calibration should remain intact. The preset slots will be lost though -- the versioning isn't particularly smart.

SimonKunz commented 3 years ago

I don't even use the preset slots to be honest. Thank you :-)