Simple moving average is applied for INA219 measurements by default with window size 5. Could be changed with sma_samples param
batteries_count parameter for 12.6V UPS Hat versions with 3 batteries in series. Used in SoC calculations
Doubled window size is used for calculation of SoC, Remaining Battery Capacity and Remaining Time to provide even more smoothing
Filtering of the INA219 measurements implemented in wrapper class
Due to sensor readings count and memory optimisations, actual measurement and storing values to buffers moved to separate method. It may be additionally sampled if needed (for example on every HA update read INA219 data 5 times with 100ms intervals and count additional mean on every single value)