Closed paolafer closed 1 year ago
For reference, these plots show a proxy[^1] the position of the SiPMs in the current master and with the changes implemented by this PR.
[^1]: The plot is generated by tracking optical photons that go into the volume "SiPMSensl"
Since tag
v6_03_00
, the geometry of the lead castle at LSC (theNext100Shielding
class) has changed quite a lot, after a thorough review and it has also been adapted to the NEXT-100 geometry. As a consequence, it cannot be used as it is in NEXT-White. In this PR we add a new class for shielding, to be used only with NEXT-White, importing theNext100Shielding
class from tagv6_02_00
and adapting it to the current nexus code. Of course, this means that the latest additions to the castle geometry are not present when using NEW.