Closed fredzo closed 1 month ago
I think this needs the submodule bump for ngscopeclient/scopehal#900. Other than that, it seems to work: there is visibly more quantization in an 8 bit capture than a 12 bit capture on my screen, and it takes much longer to download a capture!
As requested by joshua_, here is the 16bit data transfert mode for Rigol DHO models (settings part). Tested OK on my DHO804. Should work on DHO1000/4000 as well. I used the same default/8bit/16bit setting system as for Siglent HD models. Goes with the companion PR on scopehal : https://github.com/ngscopeclient/scopehal/pull/900