Open nipunbatra opened 11 years ago
After plotting this we can identify that some appliance is turned on but I feel some noise is coming. This CT is having only refrigerator or something else as well ?.
https://github.com/nipunreddevil/Home_Deployment/blob/master/configuration/circuits.md
shows the mapping.
Barring RO rest all appliances are Off.
Can you do a small test as of now:
Than it will be easy to understand from where this noise is originating and how we can reduce that.
Ok. Will do the tests and report the results.
I feel this board is more noisy than previous one. I had tried to log data from Winet for 2 hours and data was clean enough. I can add some filters to reduce these low freq spikes.
All appliances on CT number 4 off (turned OFF Ref. and RO). With no load on this CT, it is showing a lot of fluctuation. Readings from other CT's also mentioned here for reference.
Time, CT#, Current
1372936421.51,4, 0.4147
1372936421.59,0, 0.3110
1372936421.68,1, 0.3110
1372936421.76,2, 0.2074
1372936421.85,3, 0.3110
1372936421.93,4, 0.1037
1372936422.02,0, 0.1037
1372936422.1,1, 0.3110
1372936422.19,2, 0.1037
1372936422.27,3, 0.2074
1372936422.36,4, 0.1037
1372936422.44,0, 0.3110
1372936422.53,1, 0.4147
1372936422.61,2, 0.2074
1372936422.69,3, 0.3110
1372936422.78,4, 0.4147
1372936422.86,0, 0.4147
1372936422.95,1, 0.6221
1372936423.03,2, 0.4147
1372936423.12,3, 0.3110
1372936423.2,4, 0.3110
1372936423.29,0, 0.1037
1372936423.37,1, 0.3110
1372936423.46,2, 0.2074
1372936423.54,3, 0.1037
1372936423.63,4, 0.1037
1372936423.71,0, 0.2074
1372936423.79,1, 0.3110
1372936423.88,2, 0.2074
1372936423.96,3, 0.2074
1372936424.05,4, 0.4147
1372936424.13,0, 0.4147
1372936424.22,1, 0.3110
I feel 2 reasons in this case
If you feel data is not useful than please remove this circuit i will modify this to ensure minimal noise interference.
Ok. Currently testing the WiNet based CT circuit to see if that has noise in it or not.
Following are 7 test cases i performed
@manojgulati : If you would like to pan and zoom into these plots, the script used is here https://dl.dropboxusercontent.com/u/75845627/Deployment/ct_data/ct_data_plot.py
These graphs seems to be much cleaner than previous one. If you do remember ADC was giving +/- one point fluctuation so similar effect is reflected in final current calculation as well. But if you notice mean is still constant we can find average of this to find out actual current.
Do you feel value of current that you are getting is also erroneous ? Because i am not having idea like how much current should be there in these specific load conditions.
Log for Circuit 4 (only refrigerator on at this time, RO water purifier also connected, but i think it will consume significant current only when it needs to fill its tank)
This is the CT log when compressor was Off. During this time jPlug was showing current ~0
This is the CT log when compressor was On. During this time jPlug was showing a current of 0.42 A
cc @amarjeet-iiitd