salman373 commented 5 years ago

Hi, I am very happy to get the Time Switch setting and it is working fine. but a small issue with me that is when it switch to Solar then i get SBU setting that is fine. but when it convert back to Grid it shift to UTI but i want it to be in SOL setting when back to grid. Each day end i convert it to SOL and in Morning it switch fine to SBU but in evening it should convert back to SOL not to UTI. Thanks

njfaria commented 5 years ago

If you set SOL it changes to Grid at evening ( no Sun ) SOL is Solar first then battery. Grid provides power only if Solar is not available As long as the sun is shining you are on Solar/Battery After Sun is gonne it changes to Grid. You wouldnt either need the timeswitch.... but i should add switch to SOL

njfaria commented 5 years ago

v2.5.5 suporting switch to SOL